The horn – DB3B UL

Français

The horn – DB3B UL

   TM261   April 2020   www.eaton.com

6.0 Certification/autorisations

Listé UL pour utilisation aux USA (USL) et Canada 

(CNL) - signal sonore applicable pour alarme incendie ou 

utilisation générale.
Veuillez vous référer au marquage sur l’unité pour plus de 

détails des approbations spécifiques

(USL)

Class I, Zone 1 AEx db IIC T*
Zone 21 AEx tb IIIC

(CNL)

Class I, Zone 1 Ex db IIC Gb T*
Class II, Zone 21, Ex tb IIIC Db

Convient également pour:

Class I, Div. 2 Groups A, B, C, D
Class II, Div. 2, Groups F et G
Class III, Div. 1

Normes applicables:
(USL)

UL 60079-0, Edition7
UL 60079-1, Edition 7
ANSI/ISA 60079-31, Edition 2 
UL 464, Edition 9

(CNL)

CSA C22.2 No. 60079-0:19
CSA C22.2 No. 60079-1:19
CSA C22.2 No. 60079-31, Edition 2
CAN/ULC-S525-07

T-nominale:

Puissance max. 

nominale

Tamb.

T-nominale (T*)

15W

-67 °F à +185 °F (-55 °C à +85 °C) T4/T135°C 
-67 °F à +131 °F (-55 °C à +55 °C) T5/T100°C
-67 °F à +104 °F (-55 °C à +40 °C) T6/T85°C

Caractéristiques électriques:

La DB3B est disponible dans un certain nombre de 

différentes tensions d’entrée:

1.  12 V à 48 V CC, 716 mA à 171 mA, Application spéciale*
2.  110 V CA, 50/60 Hz, 122 mA, Application spéciale.
3.  120 V CA, 50/60 Hz, 110 mA, Régulé.
4.  220/230/ V CA, 50/60 Hz, 63 mA, Application spéciale.
5.  240 V CA, 50/60 Hz, 58 mA, Régulé.

*Remarque: 

la version des applications spéciales CC est 

adaptée pour une utilisation avec une alimentation 24 V 

CC régulée.

7.0 Conditions spéciales pour une  

utilisation sûre

1.  En cas de remplacement, les vis de fixation du 

couvercle seront en acier inoxydable de grade A2-70 

ou plus.

2.  La peinture et la finition des surfaces, différentes 

de celles appliquées par le fabricant, ne sont pas 

autorisées.

3.  Quand l’unité est utilisée dans une atmosphère 

poussiéreuse, les entrées de câbles utilisées doivent 

être scellées afin de maintenir l’indice IP6X suivant les 

codes d’installation applicables.

4. 

Avertissement

 – Ne pas ouvrir quand une atmosphère 

explosive est présente.

5.  Pour des connexions d’alimentation, utilisez au 

minimum des câbles classés 105 °C.

6. 

Avertissement 

 

sur les unités peintes, pour éviter 

l’accumulation de charges électrostatiques, nettoyer le 

boîtier avec un chiffon humide.

7. 

Avertissement

 – afin de réduire le risque 

d’inflammation des atmosphères dangereuses, les 

ouvertures de conduits doivent avoir un raccord 

étanche relié à 50mm de l’enceinte.

8. 

Avertissement

 – Ce produit n’est pas non incendiaire. 

Il s’agit d’un produit Zone 1 Ex d. Lorsqu’il est utilisé 

dans une application de division 2 par équivalence, il 

doit être installé en tant que produit Zone 1 Ex d pour 

maintenir le type de protection.

8.0 Sécurité fonctionnelle 

Introduction

Le générateur de sons DB3B a été conçu pour être utilisé 

dans des atmosphères potentiellement explosives et des 

conditions environnementales sévères. Les boîtiers en 

polyester renforcé de fibres de verre sont adaptés à une 

utilisation off-shore ou on-shore, où un poids léger et un 

haut niveau de résistance à la corrosion sont nécessaires.
La fonction de sécurité du générateur de sons consiste à 

fournir un avertissement sonore pré- déterminé lorsque 

nécessaire, si la tension correcte est appliquée à l’unité. 

La version CC du générateur de sons est conçue pour 

fonctionner à une tension d’alimentation entre 12-48 Vcc.
Dans des conditions de fonctionnement sans défaillance 

(normales), le générateur de sons DB3B émet un 

avertissement sonore sur demande du système.
En cas de panne/défaillance, le mode de panne du 

générateur de sons est indiqué par l’échec de l’émission 

de l’avertissement sonore. Pour de plus amples détails 

sur le taux d’échec/défaillance associé à ce mode de 

panne, voir le tableau ci-dessous.

Évaluation de sécurité fonctionnelle

Le générateur de sons est destiné à être utilisé dans un 

système de sécurité conforme aux exigences IEC61508.
UL a procédé à une étude «Effet des modes de panne 

et analyse du diagnostic» (Failure Modes Effect and 

Diagnostic Analysis : FMEDA) sur le générateur de sons 

DB3B par rapport aux exigences.
IEC 61508-2, avec un intervalle entre essais de sûreté de 

8 760 heures.
Les résultats sont présentés ci-dessous et sont basés sur 

la Route 1

H

.

Le générateur de sons a été classé comme appareil de 

type B.

Summary of Contents for DB3B UL

Page 1: ...The horn DB3B UL Technical manual...

Page 2: ...URPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL...

Page 3: ...ard configuration wiring details Type 4 3 DC Version Up to 3 user selectable stages with 2 independantly powered stages Type 5 3 DC version Up to 3 stage with or without monitoring alternative configu...

Page 4: ...iv The horn DB3B UL TM261 April 2020 www eaton com...

Page 5: ...Ensure that only the correct listed or certified stopping plugs are used to blank off unused gland entry points and that the NEMA IP rating of the unit is maintained X MEDC recommend the use of a seal...

Page 6: ...es will produce no tone DC version 3 stage without monitoring wiring details Type 3 This type can be configured in a number of different ways depending on requirements Independent tone selection for a...

Page 7: ...s M1 M2 terminals ote N monitored terminals are not polarity dependent DC Version Up to 3 user selectable stages with 2 independantly powered stages Type 5 Connect up to 4 supply wires to the terminal...

Page 8: ...ation wiring details Type 7 Connect the positive ve and negative ve supply wires to the terminals as detailed in the wiring diagram When power is applied to the unit no tone will be produced initially...

Page 9: ...01101 Swedish Fire Alarm 20 Alt 554 440 Hz at 1 Hz 01100 Swedish Fire Alarm 21 Int 660 Hz at 7 8 Hz 01011 Swedish Fire Alarm 22 Int 2850 Hz 150 mS on 100 mS off 01010 Pelican Crossing 23 Sweep 800 970...

Page 10: ...T14 T10 T1 T8 T14 26 3x2850Hz pulses 0 5on 0 5off 1 5 off 00110 T14 T10 T1 T8 T14 27 Int 3100Hz 0 32s on 0 68s off 00101 T14 T10 T1 T8 T14 28 Continuous 1400Hz 00100 T14 T10 T1 T8 T14 29 Spare Custom...

Page 11: ...A Angle OSPL dBA Long Flare Version Horizontal Axis Reference 90 93 9 Reference 90 C 93 9 165 90 9 3 dBA 20 90 9 3 dBA 87 9 6 dBA 87 9 6 dBA 180 92 0 0 91 9 Long Flare Version Vertical Axis Reference...

Page 12: ...etal products However if abnormal or unusual environmental conditions occur due to plant damage or accident etc then visual inspection is recommended If the unit requires cleaning then only clean exte...

Page 13: ...0 Hz 122mA Special Applicaton 3 120 V ac 50 60 Hz 110 mA Regulated 4 220 230 Vac 50 60 Hz 63 mA Special Application 5 240 Vac 50 60 Hz 58 mA Regulated Note the DC special application version is suitab...

Page 14: ...der is intended for use in a safety system conforming to the requirements of IEC61508 UL has conducted a Failure Modes Effect and Diagnostic Analysis FMEDA of the DB3B Sounder against the requirements...

Page 15: ...for use in safety functions and the installation configuration overall validation maintenance and repair shall only be carried out by competent personnel observing all the manufacturer s conditions a...

Page 16: ...ard type 4 16 Version CC Jusqu 3 tages s lectionnables par l utilisateur avec 2 tages aliment s ind pendamment type 5 16 D tails du c blage version CC Jusqu trois tages avec ou sans surveillance confi...

Page 17: ...u certifi s doivent tre utilis s IX S assurer que seul les bouchons r pertori s corrects ou certifi s sont utilis s pour obturer les points d entr e des presse toupes inutilis s et que l indice IP NEM...

Page 18: ...teurs ne produira aucun son D tails du c blage version CC Trois tages sans surveillance type 3 Ce type peut tre configur de plusieurs mani res diff rentes en fonction des besoins La s lection ind pend...

Page 19: ...nes surveill es ne sont pas d pendantes de la polarit Version CC Jusqu 3 tages s lectionnables par l utilisateur avec 2 tages aliment s ind pendamment type 5 Branchez jusqu 4 fils d alimentation aux b...

Page 20: ...e d taill dans le sch ma de c blage L tage 1 est produit quand l alimentation est appliqu e entre les bornes du commun VE et VE de l tage 1 L tage 2 est produit quand l alimentation est appliqu e entr...

Page 21: ...12 48 V CC la gamme de tension d entr e absolue est de 11 0 V CC 58 0 V CC L unit est quip e d une commande de volume qui est positionn e sur la partie sup rieure de la platine du circuit imprim Le v...

Page 22: ...dant 0 1 S 440 Hz pendant 0 4 S 10001 Tonalit d incendie fran aise 16 Int 660 Hz 150 ms on 150 ms off 10000 Tonalit d incendie su doise 17 Int 660 Hz 1 8 sec on 1 8 sec off 01111 Tonalit d incendie su...

Page 23: ...T8 T14 16 Int 660 Hz 150 ms on 150 ms off 10000 T14 T10 T1 T8 T14 17 Int 660Hz 1 8 sec on 1 8 sec off 01111 T14 T10 T1 T8 T14 18 Int 660Hz 6 5 sec on 13 sec off 01110 T14 T10 T1 T8 T14 19 Continue 66...

Page 24: ...9 3 dBA 46 86 9 3 dBA 148 83 9 6 dBA 35 83 9 6 dBA 180 81 8 0 81 5 Axe vertical en version courte vas e R f rence 90 89 8 R f rence 90 89 8 143 86 8 3 dBA 47 86 8 3 dBA 150 83 8 3 dBA 35 83 8 6 dBA 18...

Page 25: ...es Toutefois si des conditions environnementales anormales ou inhabituelles se produisent en raison de dommages l installation ou d accident etc alors un contr le visuel est recommand Si l unit n cess...

Page 26: ...sez au minimum des c bles class s 105 C 6 Avertissement sur les unit s peintes pour viter l accumulation de charges lectrostatiques nettoyer le bo tier avec un chiffon humide 7 Avertissement afin de r...

Page 27: ...ettre l int grit de s curit de l quipement valu 1 L utilisateur est tenu de se conformer aux exigences nonc es dans la documentation utilisateur fournie par le fabricant ce Manuel de s curit et Manuel...

Page 28: ...n contained in this document and to prices are reserved so are errors and omissions Only order confirmations and technical documentation by Eaton is binding Photos and pictures also do not warrant a s...

Reviews: