The horn – DB3B UL

   TM261   April 2020   www.eaton.com

The horn – DB3B UL

English

1.0 Introduction

This range of horns, suitable for fire alarm or general use, 

is intended for use in potentially explosive gas (G) or gas 

and dust (GD) atmospheres.
The enclosure is manufactured from a UV stable glass 

reinforced polyester with a rugged thermoplastic flare. 

Stainless steel mounting bracket, cover screws and 

fixings are incorporated throughout thus ensuring a 

corrosion free product.

A UL ordinary locations listed version is also available for 

use in non-explosive atmospheres.

2.0 General safety messages and  

warnings

All instructions and safety messages in this manual must 

be followed to allow safe installation of the device. The 

device must only be installed and maintained by correctly 

trained site personnel/installers.

I.    To reduce the risk of ignition of hazardous 

atmospheres and shock, do not apply power to the 

device until installation has been completed and the 

device is fully sealed and secured.

II.  To reduce the risk of ignition of hazardous 

atmospheres and shock, keep device tightly closed 

when the circuit is energised.

III.  Before removing the cover for installation or 

maintenance, ensure that the power to the device 

is isolated.

IV.  Following installation, test the device to ensure 

correct operation.

V.  Following installation ensure a copy of this manual 

is made available to all operating personnel.

VI.  When installing the device, requirements for 

selection, installation and operation should be 

referred to e.g. IEE Wiring Regulations and the 

‘National Electrical Code’ in North America. Additional 

national and/or local requirements may also apply.

VII.  Cable termination should be in accordance with the 

specification applying to the required application. 

MEDC recommends that all cables and cores should 

be correctly identified. Please refer to the wiring 

diagram in this manual (or separate diagram provided 

with the unit).

VIII. This is an Ex d product, correctly listed or certified 

explosion proof cable glands and stopping plugs must 

be used.

IX.  Ensure that only the correct listed or certified 

stopping plugs are used to blank off unused gland 

entry points and that the NEMA/IP rating of the unit 

is maintained.

X.  MEDC recommend the use of a sealing compound 

such as HYLOMAR PL32 on the threads of all glands 

and stopping plugs and/or a suitable sealing washer 

in order to maintain the IP rating of the unit.

XI.  The internal earth terminal 

 must be used for 

protective earthing when required. Do not remove 

the internal ground strap from the earth terminal 

where fitted.

 

For units with metric entries; gland continuity and 

earthing my be achieved with an optional external 

earth plate. If the external plate is fitted, a thread 

sealing compound such as HYLOMAR PL32 must be 

employed to maintain the IP rating of the unit.

XII.  When installing the device, MEDC recommends the 

use of stainless steel fasteners. Ensure that all nuts, 

bolts and fixings are secure.

XIII. The unit should be positioned such that debris, dust 

or water cannot settle in the re-entrant horn.

XIV. The unit should be positioned such that any solid 

object, not part of the equipment, is a minimum of 

40mm from the Ex d flamepath joint.

3.0 Installation

The unit is mounted via 2 off Ø23/64” (Ø9mm) fixing 

holes in the U-shaped stirrup/mounting bracket. If 

required, the unit can be initially placed via the Ø33/64” 

(Ø13mm) central hole in the stirrup. The unit can then 

be rotated to the required position and fixed via the 

other holes.

If ordered with the unit, a swivel mounting bracket option 

is available to allow further rotational adjustment to 

the unit.

The fixing holes have been designed to accept an Ø5/16” 

(M8) screw or bolt.

Access to terminals

The cover is secured with 6 off M5 cover screws 

(4.0mm A/F hexagon key). Once the cover fixings are 

unscrewed, the cover can be lifted away from the 

enclosure to gain access to the interior. The cover fixings 

are captive and will remain in the cover.
Once termination is complete, carefully replace the 

cover assembly back onto the body, avoiding damage to 

the mating surfaces. Tighten the cover screws evenly. 

Ensure the O-ring is seated correctly on the cover during 

reassembly. Ensure the required maximum gap of 

0.0015” (0.038mm) is maintained between the cover and 

the enclosure body once assembled.

Summary of Contents for DB3B UL

Page 1: ...The horn DB3B UL Technical manual...

Page 2: ...URPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL...

Page 3: ...ard configuration wiring details Type 4 3 DC Version Up to 3 user selectable stages with 2 independantly powered stages Type 5 3 DC version Up to 3 stage with or without monitoring alternative configu...

Page 4: ...iv The horn DB3B UL TM261 April 2020 www eaton com...

Page 5: ...Ensure that only the correct listed or certified stopping plugs are used to blank off unused gland entry points and that the NEMA IP rating of the unit is maintained X MEDC recommend the use of a seal...

Page 6: ...es will produce no tone DC version 3 stage without monitoring wiring details Type 3 This type can be configured in a number of different ways depending on requirements Independent tone selection for a...

Page 7: ...s M1 M2 terminals ote N monitored terminals are not polarity dependent DC Version Up to 3 user selectable stages with 2 independantly powered stages Type 5 Connect up to 4 supply wires to the terminal...

Page 8: ...ation wiring details Type 7 Connect the positive ve and negative ve supply wires to the terminals as detailed in the wiring diagram When power is applied to the unit no tone will be produced initially...

Page 9: ...01101 Swedish Fire Alarm 20 Alt 554 440 Hz at 1 Hz 01100 Swedish Fire Alarm 21 Int 660 Hz at 7 8 Hz 01011 Swedish Fire Alarm 22 Int 2850 Hz 150 mS on 100 mS off 01010 Pelican Crossing 23 Sweep 800 970...

Page 10: ...T14 T10 T1 T8 T14 26 3x2850Hz pulses 0 5on 0 5off 1 5 off 00110 T14 T10 T1 T8 T14 27 Int 3100Hz 0 32s on 0 68s off 00101 T14 T10 T1 T8 T14 28 Continuous 1400Hz 00100 T14 T10 T1 T8 T14 29 Spare Custom...

Page 11: ...A Angle OSPL dBA Long Flare Version Horizontal Axis Reference 90 93 9 Reference 90 C 93 9 165 90 9 3 dBA 20 90 9 3 dBA 87 9 6 dBA 87 9 6 dBA 180 92 0 0 91 9 Long Flare Version Vertical Axis Reference...

Page 12: ...etal products However if abnormal or unusual environmental conditions occur due to plant damage or accident etc then visual inspection is recommended If the unit requires cleaning then only clean exte...

Page 13: ...0 Hz 122mA Special Applicaton 3 120 V ac 50 60 Hz 110 mA Regulated 4 220 230 Vac 50 60 Hz 63 mA Special Application 5 240 Vac 50 60 Hz 58 mA Regulated Note the DC special application version is suitab...

Page 14: ...der is intended for use in a safety system conforming to the requirements of IEC61508 UL has conducted a Failure Modes Effect and Diagnostic Analysis FMEDA of the DB3B Sounder against the requirements...

Page 15: ...for use in safety functions and the installation configuration overall validation maintenance and repair shall only be carried out by competent personnel observing all the manufacturer s conditions a...

Page 16: ...ard type 4 16 Version CC Jusqu 3 tages s lectionnables par l utilisateur avec 2 tages aliment s ind pendamment type 5 16 D tails du c blage version CC Jusqu trois tages avec ou sans surveillance confi...

Page 17: ...u certifi s doivent tre utilis s IX S assurer que seul les bouchons r pertori s corrects ou certifi s sont utilis s pour obturer les points d entr e des presse toupes inutilis s et que l indice IP NEM...

Page 18: ...teurs ne produira aucun son D tails du c blage version CC Trois tages sans surveillance type 3 Ce type peut tre configur de plusieurs mani res diff rentes en fonction des besoins La s lection ind pend...

Page 19: ...nes surveill es ne sont pas d pendantes de la polarit Version CC Jusqu 3 tages s lectionnables par l utilisateur avec 2 tages aliment s ind pendamment type 5 Branchez jusqu 4 fils d alimentation aux b...

Page 20: ...e d taill dans le sch ma de c blage L tage 1 est produit quand l alimentation est appliqu e entre les bornes du commun VE et VE de l tage 1 L tage 2 est produit quand l alimentation est appliqu e entr...

Page 21: ...12 48 V CC la gamme de tension d entr e absolue est de 11 0 V CC 58 0 V CC L unit est quip e d une commande de volume qui est positionn e sur la partie sup rieure de la platine du circuit imprim Le v...

Page 22: ...dant 0 1 S 440 Hz pendant 0 4 S 10001 Tonalit d incendie fran aise 16 Int 660 Hz 150 ms on 150 ms off 10000 Tonalit d incendie su doise 17 Int 660 Hz 1 8 sec on 1 8 sec off 01111 Tonalit d incendie su...

Page 23: ...T8 T14 16 Int 660 Hz 150 ms on 150 ms off 10000 T14 T10 T1 T8 T14 17 Int 660Hz 1 8 sec on 1 8 sec off 01111 T14 T10 T1 T8 T14 18 Int 660Hz 6 5 sec on 13 sec off 01110 T14 T10 T1 T8 T14 19 Continue 66...

Page 24: ...9 3 dBA 46 86 9 3 dBA 148 83 9 6 dBA 35 83 9 6 dBA 180 81 8 0 81 5 Axe vertical en version courte vas e R f rence 90 89 8 R f rence 90 89 8 143 86 8 3 dBA 47 86 8 3 dBA 150 83 8 3 dBA 35 83 8 6 dBA 18...

Page 25: ...es Toutefois si des conditions environnementales anormales ou inhabituelles se produisent en raison de dommages l installation ou d accident etc alors un contr le visuel est recommand Si l unit n cess...

Page 26: ...sez au minimum des c bles class s 105 C 6 Avertissement sur les unit s peintes pour viter l accumulation de charges lectrostatiques nettoyer le bo tier avec un chiffon humide 7 Avertissement afin de r...

Page 27: ...ettre l int grit de s curit de l quipement valu 1 L utilisateur est tenu de se conformer aux exigences nonc es dans la documentation utilisateur fournie par le fabricant ce Manuel de s curit et Manuel...

Page 28: ...n contained in this document and to prices are reserved so are errors and omissions Only order confirmations and technical documentation by Eaton is binding Photos and pictures also do not warrant a s...

Reviews:

Related manuals for DB3B UL