Derating

DX-EM12-…

DX-EMC34-…

Mains (TN, TT)

U

LN

: 230 - 520 V +10 %, 50/60 Hz

TN-S

TN-C

TT

Installation altitude

Ambient temperature

DX-EMC 3 4 008- F S …

Frame Size (DC1, DA1)

l

e

008 = 8 A

031 = 31 A

075 = 75 A

U

LN

(Mains), 50/60 Hz

2 = 230 V (max. 250 V +10 %)

4 = 400 V (max. 520 V +10 %)

Mains

1 = 1 AC (1 phases)

3 = 3 AC (3 phases)

L1

N

L1’

N’

L2

L1

L3

L1’

L2’

L3’

L2

N

L1

L3

PE

L2

PEN

L1

L3

L2

N

L1

L3

h

I/I

e

1000 m

3280.84 ft

1

1500 m

4921.26 ft

0.98

2000 m

6561.68 ft

0.95

2500 m

8202.1 ft

0.93

3000 m

9842.52 ft

0.90

3500 m

11482.94 ft

0.88

4000 m

13123.36 ft

0.85

t

a

[°C]

t

a

[°F]

I/I

e

55

131

0.93

60

140

0.85

Summary of Contents for DX-EMC12 Series

Page 1: ...rovádět pouze osoby s elektrotechnickým vzděláním Eluohtlik Elektrilöögioht Järgnevalt kirjeldatud töid tohib teostada ainult elektriala spetsialist vői elektrotehnilise instrueerimise läbinud personal Életveszély az elektromos áram révén Csak elektromos szakemberek és elektrotechnikában képzett személyek végezhetik el a következőkben leírt munkákat Elektriskā strāva apdraud dzīvību Tālāk aprakstī...

Page 2: ...A 031 31 A 075 75 A ULN Mains 50 60 Hz 2 230 V max 250 V 10 4 400 V max 520 V 10 Mains 1 1 AC 1 phases 3 3 AC 3 phases L1 N L1 N L2 L1 L3 L1 L2 L3 L2 N L1 L3 PE L2 PEN L1 L3 L2 N L1 L3 h I Ie 1000 m 3280 84 ft 1 1500 m 4921 26 ft 0 98 2000 m 6561 68 ft 0 95 2500 m 8202 1 ft 0 93 3000 m 9842 52 ft 0 90 3500 m 11482 94 ft 0 88 4000 m 13123 36 ft 0 85 ta C ta F I Ie 55 131 0 93 60 140 0 85 ...

Page 3: ...7 25 0 98 12 5 0 49 180 7 09 200 7 87 1 3 2 87 DX EMC34 011 FS2 107 4 21 85 3 35 11 0 43 270 10 63 255 7 10 07 50 1 97 25 0 98 12 5 0 49 200 7 87 220 8 66 1 8 3 97 DX EMC34 015 FS3 131 5 16 100 3 94 16 3 0 64 312 12 28 297 7 11 72 50 1 97 25 0 98 12 5 0 49 280 11 02 300 11 81 2 3 0 09 DX EMC34 025 FS3 131 5 16 100 3 94 16 3 0 64 312 12 28 297 7 11 72 50 1 97 25 0 98 12 5 0 49 280 11 02 300 11 81 2...

Page 4: ...2017Z 4 7 FS1 FS2 FS3 FS4 FS5 DC1 IL040059ZU DA1 IL04020010Z IL L1 L L2 N L3 U V W 1 2 3 4 5 6 7 8 9 10 11 1 3 Nm 11 5 lb in 2 1 3 L1 L L2 N L3 U V W 1 2 3 4 5 6 7 8 9 10 11 DA1 IL04020011Z IL 1 3 8 Nm 70 8 lb in 2 ...

Page 5: ...одключать только в обесточенном состоянии VIGYÁZAT Csak feszültségmentes állapotban csatlakoztassa DİKKAT Sadece gerilim sıfırken bağlayın VOORZICHTIG Alleen in spanningsloze toestand aansluiten UZMANĪBU Pieslēgt tikai tad kad nenotiek sprieguma padeve УВАГА Підключати лише за відсутності напруги FORSIGTIG Må kun tilsluttes i spændingsfri tilstand PERSPĖJIMAS Prijungti tik tada kai i jungta įtampa...

Page 6: ...C1 IL040059ZU DA1 IL04020010Z IL IP20 M 3 L1 L L2 N L3 DC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 COM U DC BR V W L1 L L2 N L3 DC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 COM U DC BR V W DA1 IL04020011Z IL IP20 FAN DC BR DC L1 L2 L3 U V W ...

Page 7: ...di dispersione supera i 5 milliampere alta corrente di dispersione Per prima cosa collegare a massa La tensione pericolosa può comparire sui terminali fino a 60 secondi dopo il disinserimento UPOZORNĔNİ Svodový proud překračuje vysoký svodový proud 5 miliampérů Nejprve zapojte uzemnění Na svorkách mů e být a 60 s po vypnutí přítomno nebezpečné napětí ATENTIE Curentul de scurgere depășește 5 mA cur...

Reviews: