MN05401010E
3
english
4.1 Polarity of the inputs
npn: sinking sensor
pnp: sourcing sensor
4.2 Switching on the 30 Hz filter
(INP A)
It can be set from 00.0001
up to 99.9999.
“0” is not accepted!
4.3 Multiplying factor
(totalizer)
It can be set from 00.0001
up to 99.9999.
“0” is not accepted!
4.4 Dividing factor
( totalizer)
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
4.5 Decimal point
(totalizer)
4.6 RESET mode
(totalizer)
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
4.7 Multiplying factor
(frequency meter)
It can be set from 00.0001
up to 99.9999.
“0” is not accepted!
It can be set from 00.0001
up to 99.9999.
“0” is not accepted!
4.8 Dividing factor
(frequency meter)
The decimal point defines
the resolution in the select-
ed measuring range 1/min
or 1/sec
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
4.9 Decimal point
(frequency meter)
The filter provides input
damping*
30 Hz filter off (fmax)
30 Hz filter on
* where bounce occurs, e.g. with contacts
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 3