4 Wiring with
4.5 Counter
94
Operating instructions
05/10 MN05013003Z-EN
www.eaton.com
4.5 Counter
easy provides 16 up/down counters C1 to C16 for use as required. The counter
relays allow you to count events. You can define an upper threshold value as a
comparison value. The contact will switch according to the actual value.
4.5.0.1 High-speed counters, frequency counters up to 1 kHz counter frequency.
easy-DA and easy-DC feature four high-speed counters C13 to C16. The
function is defined by the mode selected. The counter input is connected
directly to a digital input. The high-speed digital inputs are I1 to I4. Possible
applications include the counting of components, lengths, events and
frequency measurement.
Table 13:
Counter modes
Counters C1…C16 (Counter)
Boolean inputs/outputs
Parameters
Contact
Coil
Input value
Output value
C
"1“, when actual value
≧
setpoint value
CC
Counter
input
-
-
DC
Count
direction
RC
Reset
S
setpoint value
00000 - 32000
→
The counters of easy500 and easy700 function in the same way
as the counters of easy400 and easy600. If required, the same
counters can be used retentively.
Counter
Operating
Mode
C1 to C12
N
Up/Down Counter
C13, C14
N or H
Up/down counters or high-speed up counters (easy-DA, easy-DC)
C15, C16
N or F
Up/down counters or frequency counters (easy-DA, easy-DC)
Summary of Contents for easy500, easy700
Page 4: ...II...
Page 28: ...1 1 5 operating principles 24 Operating instructions 05 10 MN05013003Z EN www eaton com...
Page 210: ...7 What Happens If 7 3 Event 206 Operating instructions 05 10 MN05013003Z EN www eaton com...