background image

5011630506-C206

2007-05-08

ELC-PC12NNDR/T
ELC-PC12NNAR

Logic Controller with Multi-Function, 

Multiple Commands

Instruction Sheet

WARNING 

x

This Instruction Sheet only provides descriptions for electrical specifications, general specifications, 

installation & wiring, troubleshooting and peripherals. Other detail infromation about programming and 

commands is compatible with ELC-PC/PA/PH series; please see ELC Application Manual. For more 

information about the optional peripherals , please see individual product manual. 

x

This is an OPEN TYPE Controller. The ELC should be kept in an enclosure away from airborne dust, humidity, 

electric shock risk and vibration. Also, it is equipped with protective methods such as some special tools or 

keys to open the enclosure, so as to avoid the hazard to users and the damage to the ELC. 

x

Never connect the AC main circuit power supply to any of the input/output terminals, as it will damage the 

ELC.    Check all the wiring prior to power up. To avoid any electromagnetic noise, make sure the ELC is 

properly grounded 

. Do NOT touch terminals when power on. 

x

Battery replacement: use UL component type: TDRTL-2150/S lithium battery. Refer to following table for 

battery life. (NOTE: RTC should be reset after changing battery). 

Temperature((

̓

C)

0  25 50 70 

Life(Years) 

9 8 6 5 

Precision of calendar timer: 

At 0

̓

C/32

̓

F, less than –117 seconds error per month. 

At 25

̓

C/77

̓

F, less than 52 seconds error per month. 

At 55

̓

C/131

̓

F, less than –132 seconds error per month. 

x

Warning – Do not disconnect while circuit is live unless area is known to be non-hazardous. 

x

Power, input and output (I/O) wiring must be in accordance with Class 1, Div. 2 wiring methods - Article 

501-10(B)(1) of the National Electrical Code. 

x

Suitable for use in Class 1, Division 2, Groups A, B, C, D or Non-Hazardous locations only. 

x

Warning – Explosion hazard - Substitution of components may impair suitability for Class 1, Division 2. 

x

Warning – Wxplosion hazard - Do not disconnect equipment unless power has been switched off or the area 

is known to be Non-Hazardous. 

1

INTRODUCTION 

1.1  Model Name Explanation and Peripherals 

Thank you for choosing Eaton Logic Controller (ELC) series products. The ELC-PC series has a 12-points (8 input 

 4 outputs) ELC main processing unit with multiple commands for use. It also has an 8K Steps program 

memory to connect to every ELC-PC series expansion unit, including digital I/O (Maximum 128 Inpus / 128 Outputs 

expansion points), analog module, etc. for various applications. 

ʳ

1.2  Product Profile and Outline 

E

L

C-P

C

1

2

NN

A

R

Y3

RS

-2

3

2

RS

-4

8

5

Y1

Y2

C2

Y0

C1

RUN

RUN

ERROR

POWER

Unit: mm 

Warning: Battery replacement: Please change the battery within 3 

minutes, or the internal data of the ELC (including the program area, 

perpetual calendar and latched registers) could be lost or destroyed. 

1 Status indicator: POWER, RUN, 

ERROR, BAT.LOW 

2 RUN/STOP switch 

3 VR0: M1178 Start-up/D1178 

Corresponding value 

4 VR1: M1179 Start-up/D1179 

corresponding value 

5 DIN rail clip 

6 I/O terminals 

7 I/O point indicators 

8 COM1 (RS-232) (Rx) indicator 

9 COM2 (RS-485) (Tx) indicator 

10 COM1 (RS-232) programming port 

11  Nameplate 

12 Expansion port 

13 Mounting hold of the expansion unit 