5

MAU-00033 AE

Technical characteristics

Performances tested according to IEC 61643-1 (class 3) standard for 8/20 µs surge wave

600

 Nominal input voltage

 Input frequency

 Voltage/frequency of battery backup 

 

outlets

   9   

in battery mode

 Total output current for all outlets

 Output current of battery backup outlets   

9

 Leakage current

 Input protection

 Transfer time

 Telephone surge protection

 Sealed lead-acid battery

 Automatic battery test

 Average battery life

 

 Operating temperature

 Storage temperature

 Operating relative humidity

 Operating elevation

 Safety standards

 Electromagnetic compatibility standards

 Warranty

 Dimensions (mm)

 Weigth (Kg)

165V - 285V, adjustable to 150V - 285 or 175V - 285V

50/60 Hz (46 - 70 Hz working range)

230 V ± 7% (50/60 Hz ± 1 Hz) with pseudosinusoidal wave

 

0.17 mA

10 A resettable circuit breaker

10 ms typical

Tel, ISDN, ADSL, Ethernet

Once a week

4 years typical, depending on number of discharge cycles and 

temperature

0 to 35°C

-25°C to +55°C

0 to 85%

0 to 3000 m

IEC 62040-1-1, CE certified

IEC/EN 62040-2

2 years

3.7 A max

6.5 A max

2x12V, 9Ah

 Uoc (common mode / differential mode)

 Up (common mode / differential mode)

 In

 Imax

2.5 kA

8 kA

AC input source protection, Ellipse:

 

UPS

 power

600 VA /  

360W

850

2.6 A max

12 V, 7 Ah

1100

850VA /  

550 W

1500

1100 VA /  

660 W

1500 VA /  

900 W

2x12V, 7Ah

10 A max

600

1100

1500

6kV/2kV

1.5kV/1.5kV

310x 82x 301

6

10

10.2

Ellipse MAX:

4.8 A max

2x12V, 7Ah

310x82x410

850

6kV/2kV

1.5kV/1.3kV

Summary of Contents for Ellipse MAX 600

Page 1: ...Installation and user manual English Français Deutsch Italiano Español Nederlands Português Polski Česky Solvenčina Slovensko Magyar Türkçe Ellipse MAX 600 850 1100 1500 Pulsar Series www eaton com ...

Page 2: ...2 MAU 00033 AE Packaging 3 5 1 2 4 Ellipse MAX Ellipse MAX Ellipse MAX MAX MAX MAX MAX MAX MAX MAX MAX MAX MAX MAX MAX Product should put on right direction as show above ...

Page 3: ...3 MAU 00033 AE Quick start A A FR DIN IEC UNIVERSAL 3 6 B C D Ellipse Max 600 Ellipse Max 850 1100 1500 USBS 3 6 C D Ellipse Max 600 USBS B ...

Page 4: ... black when connecting the batteries as this will destroy the device Attention lors du raccordement des batteries une inversion des polarités rouge et noir provoque la destruction de l appareil OFF OFF a 7 b d f e b c a d e f The battery elements must be replaced exclusively by qualified personnel risk of electrocution Les éléments batterie ne peuvent être remplacés que par du personnel qualifié r...

Page 5: ...arranty Dimensions mm Weigth Kg 165V 285V adjustable to 150V 285 or 175V 285V 50 60 Hz 46 70 Hz working range 230 V 7 50 60 Hz 1 Hz with pseudosinusoidal wave 0 17 mA 10 A resettable circuit breaker 10 ms typical Tel ISDN ADSL Ethernet Once a week 4 years typical depending on number of discharge cycles and temperature 0 to 35 C 25 C to 55 C 0 to 85 0 to 3000 m IEC 62040 1 1 CE certified IEC EN 620...

Page 6: ... the UPS press button 13 for about 1 second Filtered outlets 8 without battery backup Equipment connected to these outlets is supplied as soon as the AC cord 2 is plugged in They are not affected by button 13 Battery backup outlets 9 Equipment connected to these outlets is supplied as soon as button 13 turns green see figure E These outlets can be turned on even if the UPS is not connected to AC p...

Page 7: ...nt and reset the circuit breaker 14 by pressing the corresponding button Have the electrical installation checked by a professional or use another wall outlet Disconnect excess equipment connected to the battery backup outlets 9 Call after sales support Call after sales support Disconnect the telephone line from the wall outlet Call after sales support Have the battery replaced 1 2 3 4 5 6 7 8 9 1...

Reviews: