ET4001 Crimp machine operator´s manual W-EQCR-TM022-E3 March 2019
Operating instructions
Spacer ring and nominal crimp
diameter measurement
Spacer ring
Typical spacer ring
illustrating both sides of ring
Nominal crimp diameter
measurement
Measuring crimp diameters
should be a part of the
normal hose assembly
procedure. To insure a
proper crimp diameter
reading, follow these steps:
1. Measure the diameter
in the middle of the
crimped portion of the
hose end.
2. Place the caliper in a
position to allow for a
measurement across the
pressed (flat) portion of
the crimp.
3. See crimp diameters in
crimp specifications.
Maintenance
Collet assembly lubrication
Every 30 crimps
= Re-lubricate sliding surfaces of dies
Every 250 crimps = Remove old grease and re-lubricate
Base adapter ring lubrication
Every 250 crimps = Remove old grease and re-lubricate
Every 1,000 crimps = Remove old grease, inspect for
wear or damage and re-lubricate
if okay.
Flat side
Counterbore side
Refer to safety information regarding Eaton hose,
hose fittings, and assembly compatibility on page 2.