USER MANUAL FERNTEL IP4 / IP160
March 2022 www.eaton.com
Equipment to be switched on/off is to be connected to the connecting cables leading out of cable inlets (vi) and (vii),
which are connected with electromechanical relays, relay 1 (vi) and relay 2 (vii). The changeover contact of both relays can
switch DC and AC current loads in the indicated load range.
The position of the cable inlets can be found in Figure 1 “- Housing top view and position of the wire/cable inlets (i) – (viii)”
on page 8.
2.4.7 Output contacts relay 1 and relay 2
+/~
-/~
1
2
2
3
1
3
Load
Relay-2
KLE vii
+/~
-/~
Relay-1
1
2 KLE vi
2
3
1
3
Load
AC:
V
switch
≤ 250 V
AC
/ I
switch
≤ 5.0 A
AC
S
switch
(V
switch
> 35 V
AC
) ≤ 15 VA
S
switch
(V
switch
≤ 35 V
AC
) ≤ 100 VA
DC:
V
switch
≤ 230 V
DC
/ II
switch
≤ 5.0 A
DC
P
switch
(V
switch
> 50 V
DC
) ≤ 15 W
P
switch
(V
switch
≤ 50 V
DC
) ≤ 100 W
Please perform a final check of the mountings and connections to ensure perfect commissioning and safety.
Connect the keyboard (6) via the plug-in connection (7) with the circuit board located in the interior of the housing.
Then secure the used keyboard with the 4 screws (8).
2.5 Concluding work
The external DC power supply is to be connected to terminals 7 and 8 of the terminal strip X located in the terminal
compartment.
Make sure that you use sufficient conductor cross-sections so that the minimum required DC voltage is available on the
terminals. You can find more information about this in the technical data section of this user manual.
2.4.6 External power supply DCPower
22.8 V
DC
V
DCPower
53.0 V
DC
I
DCPower
600 mA
DC
P
DCPower
15.00 W
+
+
-
SMPS
7
8
AC:
V
switch
≤ 250 V
AC
/ I
switch
≤ 5.0 A
AC
S
switch
(V
switch
> 35 V
AC
) ≤ 15 VA
S
switch
(V
switch
≤ 35 V
AC
) ≤ 100 VA
DC:
V
switch
≤ 230 V
DC
/ II
switch
≤ 5.0 A
DC
P
switch
(V
switch
> 50 V
DC
) ≤ 15 W
P
switch
(V
switch
≤ 50 V
DC
) ≤ 100 W
Attention!
- Only ES1 and PS1 classified power supplies in accordance with EN 62368-1 may be used to supply the phone.
- If you supply the phone via connectors X1.7 and X1.8, your LAN1 connecting cable must not conduct any PoE supply (Power over
Ethernet).
Attention!
- The permitted load currents of the output contacts are voltage dependent. Calculate their maximum values as indicated below by
generating the quotient of switching-voltage-dependent switch rating Pswitch(Vswitch) and switching voltage Vswitch. Furthermore,
the result must not exceed the indicated maximum value of the switching current Iswitch.
AC: I
LoadMax
= S
switch
(V
switch
) / V
switch
= 15 VA / 48 V = 0.312 A I
LoadMax
≤ I
switchMax
!
DC: I
LoadMax
= P
switch
(V
switch
) / V
switch
= 100 W / 48 V = 2.08 A I
LoadMax
≤ I
switchMax
!
- The electric circuits of the switching contacts of both relays must not be interconnected with different external conductors of an AC network.