42
Troubleshooting
1
General Information
2nd Ed. 02/07
FSO-2405
Problem
Probable cause
Possible solution
Reference
Bearing failures
Mainshaft or
Adjust end play
End play
(continuation)
countershaft end
adjustment -
play improperly
page 148
adjusted
Bearings were
Replace damaged
As to this manual
not lubricated
parts. Reassemble
instructions
before assembling
as to proper procedure
Double shifting
Double gear shifting Reassemble
As to this manual
interlocking system
properly
instructions -
improperly
page 134
assembled