 www.eaton.com   3 

Accessories (sold 
Separately) 

• ELC-CBPCELC1 — 1 meter cable to 

connect between the 

HM

i

 

and Eaton Logic 

Controller (ELC) 

• HMIEC0806 — 8 DC In, 6 Relay Outputs 

expansion module for local logic 

• HMIEC1612 — 16 DC In, 12 Relay Outputs 

expansion module for local logic 

• HMIECENT — Ethernet expansion card 

for Modbus TCP communications and 

application upload/download 

• ELC-PS01 — 1 amp 24V DC power 

supply 

• ELC-PS02 — 2 amp 24V DC power 

supply 

• HMI-SPKIT — Spare Parts Kit for 

HM

i

 

Operator Interface 

• HMI04-GASKET — 2 Spare Gaskets 

for 4" 

HM

i

 units 

• HMI06-GASKET — 2 Spare Gaskets 

for 6" 

HM

i

 units 

• HMI08-GASKET — 2 Spare Gaskets 

for 8" 

HM

i

 units 

• HMI10-GASKET — 2 Spare Gaskets 

for 10" 

HM

i

 units 

 
 
 
 

Unpack and Inspect 

Included with the 

HM

i

 

are: 

• Panel Mounting clips (number of clips 

varies depending on the size of the unit). 

• DB9 gender changer for easy connection 

to the Eaton Logic Controller (ELC). 

• 3-pin 24V DC power connector. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for HMi Series

Page 1: ...May 2010 Contents Description Page Preface 1 Safety Information 1 General Description 2 Accessories sold Separately 3 Unpack and Inspect 3 Hardware Features 4 Dimensions and Cut Outs 9 Serial Port Pi...

Page 2: ...grounding maintenance and inspection warnings and guidelines are followed For information on HMi software installation and operation please refer to the HMisoft user manual WARNING Comply with instru...

Page 3: ...any internal or exposed electrical parts of the device or electrical shock may result Do not remove the operator interface while power is applied or electrical shock may result Wait at least 10 second...

Page 4: ...cations and application upload download ELC PS01 1 amp 24V DC power supply ELC PS02 2 amp 24V DC power supply HMI SPKIT Spare Parts Kit for HMi Operator Interface HMI04 GASKET 2 Spare Gaskets for 4 HM...

Page 5: ...A Power Input Terminal B COM2 C COM1 Note D USB E Startup Switch UP position Run Mode DOWN position Boot Menu NOTE For simultaneous communications wire one DB9 connector for COM1 and COM3 according to...

Page 6: ...er Input Terminal B COM2 Note C COM1 D Battery Cover E USB Host F USB Client G System Key NOTE For simultaneous communications wire one DB9 connector for COM2 and COM3 according to the pinout diagram...

Page 7: ...06CE A Power Input Terminal B Expansion Slot C Smart Memory Card Slot D COM2 Note E COM1 F USB NOTE For simultaneous communications wire one DB9 connector for COM2 and COM3 according to the pinout dia...

Page 8: ...ut Terminal B Expansion Slot C Smart Memory Card Slot D COM2 Note E COM 1 F USB G Battery Cover NOTE For simultaneous communications wire one DB9 connector for COM2 and COM3 according to the pinout di...

Page 9: ...ut Terminal B Expansion Slot C Smart Memory Card Slot D COM2 Note E COM 1 F USB G Battery Cover NOTE For simultaneous communications wire one DB9 connector for COM2 and COM3 according to the pinout di...

Page 10: ...HMi Series Instruction Leaflet Dimensions and Cut Outs 4 HMi HMI04BU HMI04CU 6 HMi HMI06BE HMI06GE HMI06CE HMI06CU EATON CORPORATION www eaton com 9...

Page 11: ...HMi Series Instruction Leaflet 8 HMi HMI08CE 10 HMi HMI10CE EATON CORPORATION www eaton com 10...

Page 12: ...232 COM3 Not Used COM3 Used PIN COM1 COM3 COM1 COM3 1 2 RX RX 3 TX TX 4 5 GND GND GND 6 7 RTS TX 8 CTS RX 9 Not Used Note Blank No connection COM2 Pinout for RS 422 RS 485 PIN RS 422 RS 485 G GND GND...

Page 13: ...COM2 COM3 COM2 COM3 1 2 RX RX 3 TX TX 4 D 5 GND GND GND 6 7 8 9 Not Used D COM2 and COM3 DB 9 Pinout for COM2 and COM3 RS 485 COM3 Not Used COM3 Used PIN COM2 COM3 COM2 COM3 1 D D 2 3 4 D 5 GND GND GN...

Page 14: ...d PIN COM2 COM3 COM2 COM3 1 2 RX RX 3 TX TX 4 5 GND GND GND 6 7 RTS TX 8 CTS RX 9 Not Used COM2 and COM3 DB 9 Pinout for COM2 and COM3 RS 485 COM3 Not Used COM3 Used PIN COM2 COM3 COM2 COM3 1 RX RX 2...

Page 15: ...changed from the System menu 6 HMI06BE HMI06GE HMI06CE 8 HMI08CE 10 HMI10CE Recommended wiring Type Wire Gauge AWG Stripped length Torque Solid 28 12 7 8 mm 4 5 lb in Stranded 28 12 7 8 mm 4 5 lb in D...

Page 16: ...ler 206 4MHz Memory Program History Recipe Alarm Data Register Volatile Non volatile 1M 120K 64K Note 2 4K 64K 1K 3M 120K 64K Note 2 4K 64K 1K 3M 360K 128K 16K 64K 1K 3M 360K 128K 16K 64K 1K Backup Me...

Page 17: ...7 25 x 5 67 x 1 85 184 1 x 144 1 x 47 Panel Cutout W x H in Inches mm 4 68 x 3 65 118 8 x 92 8 6 79 x 5 21 172 4 x 132 4 Weight in Lbs kg 69 315 62 310 1 69 768 NIT Rating 100 cd m2 300 cd m2 130 cd...

Page 18: ...ontroller 206 4MHz 32 bit RISC Micro controller 266MHz 32 bit RISC Micro controller 206 4MHz Memory Program History Recipe Alarm Data Register Volatile Non volatile 3M 7M 7M 7M 360K 128K 16K 64K 1K 12...

Page 19: ...85 184 1 x 144 1 x 47 9 57 x 7 01 x 2 06 243 1 x 178 1 x 52 4 11 70 x 8 74 x 2 01 297 1 x 222 1 x 51 1 Panel Cutout W x H in Inches mm 6 79 x 5 21 172 4 x 132 4 9 11 x 6 55 231 4 x 166 4 11 2 28 3 x 8...

Page 20: ...HMi Series Instruction Leaflet...

Reviews: