background image

Contents

Description 

Page

1.  Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.  Receiving, Handling, and Storage . . . . . . . . . . 4
3.  Equipment Description . . . . . . . . . . . . . . . . . . 5
4.  Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.  Inspection, Testing, and Maintenance . . . . . . 14
6.  Document References . . . . . . . . . . . . . . . . . . 14

Effective June 2011

Instruction Booklet 

IB01900002E

Instructions for Magnum DS

®

 Metal-Enclosed

Low-Voltage NEMA 3R Assemblies

Summary of Contents for Magnum DS

Page 1: ...andling and Storage 4 3 Equipment Description 5 4 Installation 11 5 Inspection Testing and Maintenance 14 6 Document References 14 Effective June 2011 Instruction Booklet IB01900002E Instructions for...

Page 2: ...1 Introduction 1 1 General Information Magnum DS Metal Enclosed Low Voltage NEMA 3R Switchgear and Switchboard Assemblies are uniquely designed for use in outdoor environments or other harsh conditio...

Page 3: ...rm that all circuits are de energized before servicing 7 After maintenance be certain every current transformer second ary circuit is completely connected or shorted DANGER IF THE SECONDARY CIRCUIT OF...

Page 4: ...ial until it is certain that every item has been received in the proper condition and that certain packing material will not be required later for equipment storage Larger items such as portable trave...

Page 5: ...iptions apply to standard metal enclosed con struction and wiring Special features and control schemes are often incorporated per customer specifications These special features are evident and portray...

Page 6: ...xternal shell and the internal breaker enclosure is approximately 7 5 inches 190 mm therefore the need for a means of emergency exit is not provided Note N A unique feature of the non walk in assembly...

Page 7: ...9255C35 120 0 3047 OVERALL DEPTH 18 4 468 BUS OPENING FROM BASE 109 1 2772 105 1 2668 51 2 1301 2 0 51 4 0 102 3 9 99 2 3 58 28 6 726 FROM BASE 26 0 660 43 4 1102 AISLE WIDTH 117 1 2974 BASE 30 2 767...

Page 8: ...Assemblies EATON CORPORATION www eaton com Figure 4 Side Elevation NEMA 3R Assembly Rear Accessible without Walk in Aisle Way C C 9259C06 86 0 2185 BASE 26 0 660 28 6 726 FROM BASE 51 2 1301 2 0 51 4...

Page 9: ...ON CORPORATION www eaton com Figure 5 Side Elevation NEMA 3R Assembly Front Accessible with Walk In Aisle Way 8652C19 87 1 2211 OVERALL DEPTH 29 1 740 111 4 2830 107 9 2740 2 0 51 3 9 99 111 5 2832 OV...

Page 10: ...d Low Voltage NEMA 3R Assemblies EATON CORPORATION www eaton com Figure 6 Side Elevation NEMA 3R Assembly Front Accessible without Walk In Aisle Way 8652C25 54 2 1378 BASE 105 1 2669 110 3 2800 109 8...

Page 11: ...tion to avoid distortion of the structure The lifting plates attached at the base perform the dual purpose of providing a convenient and robust method of securing the unit to the foundation A separate...

Page 12: ...n sales office 4 4 Bus Cable and Control Connections Refer to Section 4 4 1 thru 4 4 6 of reference IB01901001E for com plete instructions and guidelines on various bus connections installa tion of po...

Page 13: ...900002E Effective June 2011 Instructions for Magnum DS Metal Enclosed Low Voltage NEMA 3R Assemblies EATON CORPORATION www eaton com Figure 10 Circuit Breaker Installation with Portable Breaker Lifter...

Page 14: ...pment Please inspect the packet attached to the outside or within an empty cell for all pertinent documentation before contact ing an Eaton service representative for replacements 2A97855 Magnum DS St...

Page 15: ...15 Instruction Booklet IB01900002E Effective June 2011 Instructions for Magnum DS Metal Enclosed Low Voltage NEMA 3R Assemblies EATON CORPORATION www eaton com Notes...

Page 16: ...ment between the parties This literature is not intended to and does not enlarge or add to any such contract The sole source governing the rights and remedies of any purchaser of this equipment is the...

Reviews: