MaGnuM PRoDuct GuiDe
CA013002EN—April 2017 www.eaton.com
19
Magnum DS - Product specific information
Magnum DS ANSI breaker product family continued
(15 through 25)
A W C H N E H K L A X
Operations counter and/
or keylock provisions
Counter
Keylock
provisions
N
K
C
R
S
A
Y
L
H
E
=
=
=
=
=
=
=
=
=
=
No counter
No counter
No counter
No counter
No counter
Counter
Counter
Counter
Counter
Counter
No locks
Kirk lock
Castell lock
Ronis lock
CES lock
No lock
Kirk lock
Castell lock
Ronis lock
indicator
CES lock
Breaker shipping options
and instructions
A
B
F
A
C
P
S
W
=
=
=
=
=
=
=
=
Fixed breaker alone with
door kit
Fixed breaker alone with door
kit and pre-wired
Fixed breaker alone without
door kit
Drawout breaker alone
without door frame kit
Drawout breaker in cassette
(un-wired)
Drawout breaker in cassette
(shutters)
Drawout breaker in cassette
(shutters)
Drawout breaker in cassette
(pre-wired and shutters)
Double frame drawout breakers
cannot ship in cassette without
cassette drawout.
Latch check switch/trip unit
metering voltage connection for
digitrip 1150 trip unit
Latch
check
switch
1150 voltage
connection
N
=
M
=
L
=
Y
=
C
=
D
=
None
None
LCS wired
to SRD
LCS Wired
to SRD
LCS Wired
External
LCS Wired
External
Upper terminals
Lower terminals
Upper terminals
Lower terminals
Upper terminals
Lower terminals
Padlock provisions for blocking
close and/or open ACB manual
pushbuttons
N
M
P
C
H
S
=
=
=
=
=
=
None
Metal (block close and open)
Plastic (block close and open)
Metal (block close only)
Plastic (block close only)
Metal swbd lock-off
(block close, depress open)
Motor operator
M
N
W
T
P
L
K
S
1
2
4
8
5
9
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Manual operated
110–125 Vac (5-sec)
110–125 Vdc (5-sec)
220–250 Vdc (5-sec)
208–277 Vac (5-sec)
24 Vdc (5-sec)
48 Vdc (5-sec)
60 Vdc (5-sec)
110–125 Vac (3-sec)
220–250 Vac (3-sec)
24 Vdc (3-sec)
48 Vdc (3-sec)
110–125 Vdc (3-sec)
220–250 Vdc (3-sec)
Spring Release Device
(SRD)
N
A
R
C
H
S
=
=
=
=
=
=
None
110–127 Vac/Vdc
208–240 Vac/Vdc
24 Vdc
48 Vdc
60 Vdc
Auxiliary switch
N
2
4
6
=
=
=
=
None
2A/2B
4A/4B
6A/6B
Shunt Trip (ST)
N
A
R
C
H
B
S
D
K
J
6
=
=
=
=
=
=
=
=
=
=
=
None
110–127 Vac/Vdc
208–240 Vac/Vdc
24 Vdc
48 Vdc
110–127 Vac/Vdc
(100% duty)
220–250 Vac/Vdc
(100% duty)
24 Vdc (100% duty)
48 Vdc (100% duty)
60 Vdc (100% duty)
60 Vdc
Bell Alarms Switch (OTS) with
2a/2b contacts and/or mechanical
trip indicator
Mech.
trip
indicator
Mech.
inter-
lock for
manual
reset
OTS
switch
with two
form C
contacts
E
N
Y
M
L
F
G
H
I
J
K
=
=
=
=
=
=
=
=
=
=
=
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
—
No
No
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
Yes
No
Yes
Yes with
24V reset
Yes with
120V
reset
Yes with
240V
reset
Yes with
24V reset
Yes with
120V
reset
Yes with
240V
reset
Frame use
X
= All breakers
Undervoltage Release (UVR)
or 2nd Shunt Trip (ST)
N
A
R
C
H
D
E
F
G
X
J
K
1
2
3
4
6
B
O
I
Q
9
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
None
UVR (110–127 Vac)
UVR (208–240 Vac)
UVR (24 Vdc)
UVR (48 Vdc)
UVR (60 Vdc)
UVR (110–125 Vdc)
UVR (220–250 Vdc)
UVR (32 Vdc)
UVR (380–415 Vac)
UVR (480 Vac)
UVR (600 Vac)
2
nd
ST (110–127 Vac Vdc)
2
nd
ST (208–250 Vac Vdc)
2
nd
ST (24 Vdc)
2
nd
ST (48 Vdc)
2
nd
ST (60 Vdc)
2
nd
ST (110–127 Vac/
Vdc 100% duty)
2
nd
ST (220–250 Vac/
Vdc 100% duty)
2
nd
ST (24 Vdc 100% duty)
2
nd
ST (48 Vdc 100% duty)
2
nd
ST (60 Vdc 100% duty)