Operating instructions ResistTel IP4/IP162
03/22
10
2.2
Montage
Insert four screws with a head diameter of 10 to 13 mm into the opening (20) and attach the telephone
base (3) to the wall or on a plate.
In the case of a telephone with a factory-fitted plastic cable entry, the telephone line must be routed
through the cable entry (KLE) (4). Inside the phone, the supplied LAN socket must be pressed onto the
cable. Using the small LAN connection cable in the phone, the connection to the electronic module can
be established via RJ45 socket X500 or X501 (see Figure 5 on page 11). The enclosed operating instruc-
tions for KLE must be observed.
Before assembly, the proper fit of the lid seal must be checked. Plug the ribbon cable from the electronic
assembly with connector (7) into the upper part of the housing on the pin header (8). Put on the top of
the telephone and attach it to the telephone base with the four cover screws (2).
In this phone, lines with dangerous voltages may be connected.
To prevent water from entering the housing, it is absolutely necessary that no seals are damaged during
assembly. The ingress of water can cause touchable parts of the phone to cause dangerous voltages.
Installation and connection must be carried out by authorized personnel with knowledge of electrical
connection technology and network technology.
If you want to operate a headset or use the output contact relay-onboard or need to operate the phone
with an external DC power supply, replace the blind plugs of the cable/line entries with appropriate
cable/line entries.
Figure 4 - Wall Mount Drilling Template