Before You Begin
Menvier30
Page 4
Do NOT site the unit:
In the entry or exit zones, or outside the area
covered by the alarm system.
Close to or on large metal structures.
Closer than one metre to mains wiring, metal
water or gas pipes, or other metal surfaces.
Lower than two metres from the floor (ideally).
Inside metal enclosures.
Next to electronic equipment, particularly
computers, photocopiers or other radio
equipment, CAT 5 data lines or industrial
mains equipment.
Note: Some window glasses, especially those
sold as
“insulating” or “energy conserving” may be
coated with thin metal or conducting films. These
glasses are particularly poor at transmitting radio
waves.
Guided Tour
CAUTION: All printed circuit boards for the
Menvier30, its expanders and keypads have been
tested for Electromagnetic Compatibility (EMC).
However, when handling the PCBs you must take
the standard precautions for handling static
sensitive devices.
Opening the Control Unit Case
To gain access to the interior of the control unit
undo the screw at the bottom of the lid. Slide the
lid vertically up, then swing the bottom of the lid
out before moving the lid down and away from the
case.
Figure 1 Opening the Control Unit.
WARNING:
When connected to the mains with
power applied mains voltages are present on the
shrouded heads of the terminal screws of the
mains connector.