7
General instructions for Multiplate couplinG
E-MEQD-II003-E December 2020 www.eaton.com
2. Second step is to move movable plate towards fixed plate in order to align mating parts.
3. Once two sub-systems are aligned, rotate the handle in counter-clockwise direction through 130° angle.
4. Verify that Red push button is moved away from plate, and “click” sound is heard to ensure connection is
complete
5. Note that safety latch will prevent accidental disconnection of system.
With these simple steps, multiplate coupling will be ready for use. It is important to follow safety instructions provided in
section 2.0 while operating Multi-FF.
For disconnection of Multi-FF, follow below listed steps:
1. Ensure that system pressure is bled-off to tank by switching to correct direction control valve position and
attachment on equipment is grounded properly. Disconnection of Multi-FF coupling under pressure is not
recommended.
2. After ensuring step 1 points, push the Red push button mounted on side face of fixed plate.
3. With red button still pushed inside, rotate the handle in clockwise direction through 130° angle, till “click”
sound is heard and handle is rested in default position.
4. Remove movable plate from fixed one and park appropriately on attachment.
5. Ensure that dust cap / cover is closed to protect top surface of fixed plate from contamination.
6. During dust cap / cover is getting closed, ensure that seal band on fixed plate is in place. If seal band is lost
or damaged, contact Eaton representative to order replacement Dust cap seal as per part number details
provided in section 8.3.