2. Connect the RDP cable to the SPD. Use tie wraps
(already on the SPD) to secure the cable to the
SPD. See Figure 16. Cable can be routed as a right
or left dress.
3. Connect the RDP cable to the display. Use tie wraps
(already on the RDP) to secure the cable to the
RDP. See Figure 17.
b. Suffix 'C': This unit is intended for use in Panelboard,
Switchboard, and Busway applications.
1. Ensure that the dead-front or door has the appro-
priate cut-out to accommodate the SPD Display.
See Figure 4 or Figure 5.
2. Install dead-front or door and secure.
c. Suffix 'J': This unit is intended for MCC applications
that require a NEMA 12 enclosure rating.
1. Ensure that the MCC bucket door has the appro-
priate cut-out to accommodate the SPD Display.
See Figure 4 or Figure 5.
2. Place an appropriate NEMA 12 rated gasket around
the Display opening on the inside of the door.
3. Install the door and secure.
Figure 16. RDP to SPD Connection
Figure 17. RDP Cable to Display Connection
6. Connect the System Ground wire (green) to the SPD’s
Surge Ground connection using a ring terminal suitable
for use with a #10 fastener and #10-32 x 3/8" fastener
(customer supplied). Tighten the Surge Ground connec-
ion to 4.1 Nm (36 in-lbs). If the system uses an isolated
ground, connect the isolated ground wire to Surge
Ground. There are two Surge Ground connection points
provided on the SPD. Connect
only one
of them. See
Figure 11.
7. If equipped, connect the System Neutral wire (grey or
white) to the SPD. Connect the System Neutral wire to
the SPD’s Neutral connection using a ring terminal suit
able for use with a #10 fastener and a #10-32 x 3/8" fas-
tener (customer supplied). Tighten the Neutral connec-
tion to 4.1 Nm (36 in-lbs). There are two Neutral connection
points provided on the SPD. Connect
only one
of them.
See Figure 12.
8. The SPD (Standard and Standard with Surge Counter
models) also has a connection available for remote
monitoring of the Form C relay contacts. See Figure 14.
This is a green connector located on the side of the SPD.
To make the connection, remove the green connector
and install the remote monitor leads (connector supports
12-24 AWG wire). Fasten the remote monitoring wires to
the N.O., N.C. and COM connection points per the label
on the front of the SPD. Contacts are rated: 150 Vac or
125 Vdc at 1A. Follow all national, state and local electrical
codes. With wiring complete, plug the green connector into
the SPD.
9. The final step of the SPD installation depends on the spe-
cific application. The various applications are listed below
by catalog suffix.
a. Suffix 'B': This is the Remote Display Panel (RDP)
option. The RDP option requires the addition of a fac-
tory supplied RDP cable. See Section 3.3, "Remote
Display Panel (RDP) Option" for Cable Catalog num-
bers.
1. Install the RDP using cutout and mounting dimen-
sions provided in Figure 15.
Figure 15. RDP Cutout and Mounting
Summary of Contents for Pow-R-Line SPX0361126
Page 2: ......
Page 4: ......
Page 6: ......
Page 7: ...TAB 1 Switchboards ...
Page 8: ......
Page 10: ......
Page 11: ...Instruction Data ...
Page 12: ......
Page 37: ...Component Data ...
Page 38: ......
Page 43: ......
Page 44: ......
Page 48: ......
Page 66: ...3 6 IM02601001E www eaton com Mechanical Installation ...
Page 114: ...14 IM02601001E www eaton com Using the I O Option Cards ...
Page 134: ...9 14 IM02601001E www eaton com Functions on the Web Server Pages Events Page ...
Page 156: ...10 22 IM02601001E www eaton com Setup on the Web Server Pages ...
Page 166: ...A 2 IM02601001E www eaton com Navigation Maps Main Menu Screens Sheet 1 ...
Page 167: ...www eaton com IM02601001E A 3 Navigation Maps Operating Mode Screens Sheet 2 ...
Page 168: ...A 4 IM02601001E www eaton com Navigation Maps Reset Mode Screens Sheet 3 ...
Page 169: ...www eaton com IM02601001E A 5 Navigation Maps Configuration Mode Screens Sheet ...
Page 170: ...A 6 IM02601001E www eaton com Navigation Maps ...
Page 172: ...B 2 IM02601001E www eaton com DIP Switch Description ...
Page 240: ...C 68 IM02601001E www eaton com Modbus Register Maps ...
Page 241: ......
Page 242: ......
Page 259: ...Shop Drawings ...
Page 260: ......
Page 262: ......
Page 264: ......
Page 266: ......
Page 268: ......
Page 270: ......
Page 272: ......
Page 274: ......
Page 275: ...Date PDF Generated 10 19 2012 Page 1 of 1 ...
Page 276: ......
Page 278: ......
Page 280: ......
Page 282: ......
Page 284: ......
Page 286: ......
Page 288: ......
Page 289: ...TAB 2 Panelboards ...
Page 290: ......
Page 292: ......
Page 293: ...Instruction Data ...
Page 294: ......
Page 296: ......
Page 325: ...Spare Parts ...
Page 326: ......
Page 371: ...Drawings ...
Page 372: ......
Page 374: ......
Page 376: ......
Page 378: ......
Page 380: ......
Page 382: ......
Page 384: ......
Page 386: ......
Page 387: ...TAB 3 Dry Type Transformers ...
Page 388: ......
Page 390: ......
Page 391: ...Instruction Data ...
Page 392: ......
Page 401: ...Drawings ...
Page 402: ......
Page 404: ......
Page 405: ...TAB 4 Molded Case Circuit Breakers ...
Page 406: ......
Page 408: ......
Page 409: ...Instruction Data ...
Page 410: ......
Page 417: ...TAB 5 Safety Switches ...
Page 418: ......
Page 420: ......
Page 421: ...Instruction Data ...
Page 422: ......
Page 424: ......
Page 452: ......
Page 453: ...Spare Parts ...
Page 454: ......
Page 467: ...Drawings ...
Page 468: ......
Page 470: ......
Page 471: ...Item 001 Cat DH261FGK ...
Page 472: ......
Page 474: ......
Page 475: ...Item 002 Cat DH261FGK ...
Page 476: ......
Page 478: ......
Page 479: ...Item 003 Cat DH261FGK ...
Page 480: ......
Page 482: ......
Page 483: ...Item 004 Cat DH261FGK ...
Page 484: ......
Page 486: ......
Page 487: ...Item 09 Cat DH364NRK ...
Page 488: ......
Page 490: ......
Page 491: ...Item 011 Cat DH324NGK ...
Page 492: ......
Page 494: ......
Page 495: ...Item 013 Cat DH362FRK ...
Page 496: ......
Page 498: ......
Page 499: ...Item 015 Cat DH321NRK ...
Page 500: ......
Page 502: ......
Page 503: ...Item 017 Cat DH362FRK ...
Page 504: ......
Page 506: ......
Page 507: ...Itm 019 Cat DH221NGK ...
Page 508: ......
Page 510: ......
Page 511: ...Item 021 Cat DH361UGK ...
Page 512: ......
Page 513: ...TAB 6 Enclosed Control NEMA ...
Page 514: ......
Page 516: ......
Page 517: ...Instruction Data ...
Page 518: ......
Page 550: ......
Page 551: ......
Page 552: ......
Page 561: ......
Page 562: ......
Page 578: ......
Page 579: ...Drawings ...
Page 580: ......
Page 582: ......
Page 584: ......