TYPICAL APPLICATION
–
ON DELAY/OFF DELAY - Timer delay occurs on
both energization and deenergization of timer.
–
CYCLE MODE - Dual delay with external connec-
tions to the NC output contact, cycles ON and OFF
continuously.
Delay mode is selectable with two switches on the face of the
timer. The time is set by a serrated dial on the module face.
Timer can also be mounted directly on 35 mm DIN rail.
•
Specifications
–
Repeat Accuracy – within
±
1%
–
Setting Accuracy –
±
10% of scale setting
PNEUMATIC TIMER
ATTACHMENT
Pneumatic Timer — The Pneumatic Timer attachment is de-
signed for snap-on installation to top of any Size 00-2 starter
(top mounted auxiliary contacts cannot be installed on device
when timer is used). It is available in two ranges from 0.1 to 180
seconds. Timer unit has D.P.D.T. timed contacts – circuits in
each pole must be the same polarity. Units are convertible from
OFF to ON delay or vice-versa. Contacts are rated A600.
Repeat accuracy is
±
10%.
INTERFACE MODULE
MOUNTED FUSE
BLOCK
CONTROL
CIRCUIT
FUSE BLOCK
TRANSIENT SUPPRESSOR KITS
FOR SIZES 00-2
FOR SIZES 3-5
Maximum Current Rating, Amperes
Description
Volts, ac
Volts, dc (Resistive)
120
240
30
Make
30
15
5
Break
3
1.5
5
Continuous
3
1.5
5
DC/AC Interface Module —
The Interface Module is an
optically isolated solid state switch which provides a
means of operating ac coils with a 24 volt dc control
signal. It acts as a space saving interposing relay which
can switch a 110-240 volt, 50/60 Hz source to the contac-
tor or starter coil.
The module may be directly attached to the coil terminals of any
Freedom Series contactor or starter - Size 00-2. It also has
provisions for DIN rail mounting.
DC Magnet Coils — Dc Magnet Coils are available either fac-
tory installed or as field conversion kits.
Transient Suppressor Kit — Sizes 00-2 device connects
across terminals on any 120 V, 240 V or 480 V starter magnet
coil and Sizes 3-5 side mounted device connects across termi-
nals on a 120 volt starter magnet coil. Suppressors are de-
signed to limit the high voltage transients produced in the circuit
when power is removed from the coil.
Control Circuit Fuse Block — Size 00-2 panel mounted and
Size 3-5 side mounted fuse holders, designed for control circuit
protection or other similar low current requirements, have ex-
tractor type fuse caps.
The Class CC rejection type fuses (KTK-R) used in these
holders are intended for use with equipment designated as
being suitable for use on systems having high available fault
currents.
If branch circuit protective device is 45 amperes or greater,
C320FBR1 fuse kit may be required for control circuit protection
per NEC 430-72.
3-Pole Top Mounted Branch Circuit Fuse Block Kits —
Designed to save space and reduce installation time, these top
mounted fuse block kits field mount to any Size 00-2 starter and
provide short circuit protection for branch circuits. Available for
Class H, R, G or T fuses rated 15 through 60 amperes and
Class J fuses rated 15 through 100 amperes, 250 through 600
volts.
NEMA, Contactors & Starters, (Freedom)
Technical Information Publication
8231
Page 5
February 2, 1998
Summary of Contents for Pow-R-Line SPX0361126
Page 2: ......
Page 4: ......
Page 6: ......
Page 7: ...TAB 1 Switchboards ...
Page 8: ......
Page 10: ......
Page 11: ...Instruction Data ...
Page 12: ......
Page 37: ...Component Data ...
Page 38: ......
Page 43: ......
Page 44: ......
Page 48: ......
Page 66: ...3 6 IM02601001E www eaton com Mechanical Installation ...
Page 114: ...14 IM02601001E www eaton com Using the I O Option Cards ...
Page 134: ...9 14 IM02601001E www eaton com Functions on the Web Server Pages Events Page ...
Page 156: ...10 22 IM02601001E www eaton com Setup on the Web Server Pages ...
Page 166: ...A 2 IM02601001E www eaton com Navigation Maps Main Menu Screens Sheet 1 ...
Page 167: ...www eaton com IM02601001E A 3 Navigation Maps Operating Mode Screens Sheet 2 ...
Page 168: ...A 4 IM02601001E www eaton com Navigation Maps Reset Mode Screens Sheet 3 ...
Page 169: ...www eaton com IM02601001E A 5 Navigation Maps Configuration Mode Screens Sheet ...
Page 170: ...A 6 IM02601001E www eaton com Navigation Maps ...
Page 172: ...B 2 IM02601001E www eaton com DIP Switch Description ...
Page 240: ...C 68 IM02601001E www eaton com Modbus Register Maps ...
Page 241: ......
Page 242: ......
Page 259: ...Shop Drawings ...
Page 260: ......
Page 262: ......
Page 264: ......
Page 266: ......
Page 268: ......
Page 270: ......
Page 272: ......
Page 274: ......
Page 275: ...Date PDF Generated 10 19 2012 Page 1 of 1 ...
Page 276: ......
Page 278: ......
Page 280: ......
Page 282: ......
Page 284: ......
Page 286: ......
Page 288: ......
Page 289: ...TAB 2 Panelboards ...
Page 290: ......
Page 292: ......
Page 293: ...Instruction Data ...
Page 294: ......
Page 296: ......
Page 325: ...Spare Parts ...
Page 326: ......
Page 371: ...Drawings ...
Page 372: ......
Page 374: ......
Page 376: ......
Page 378: ......
Page 380: ......
Page 382: ......
Page 384: ......
Page 386: ......
Page 387: ...TAB 3 Dry Type Transformers ...
Page 388: ......
Page 390: ......
Page 391: ...Instruction Data ...
Page 392: ......
Page 401: ...Drawings ...
Page 402: ......
Page 404: ......
Page 405: ...TAB 4 Molded Case Circuit Breakers ...
Page 406: ......
Page 408: ......
Page 409: ...Instruction Data ...
Page 410: ......
Page 417: ...TAB 5 Safety Switches ...
Page 418: ......
Page 420: ......
Page 421: ...Instruction Data ...
Page 422: ......
Page 424: ......
Page 452: ......
Page 453: ...Spare Parts ...
Page 454: ......
Page 467: ...Drawings ...
Page 468: ......
Page 470: ......
Page 471: ...Item 001 Cat DH261FGK ...
Page 472: ......
Page 474: ......
Page 475: ...Item 002 Cat DH261FGK ...
Page 476: ......
Page 478: ......
Page 479: ...Item 003 Cat DH261FGK ...
Page 480: ......
Page 482: ......
Page 483: ...Item 004 Cat DH261FGK ...
Page 484: ......
Page 486: ......
Page 487: ...Item 09 Cat DH364NRK ...
Page 488: ......
Page 490: ......
Page 491: ...Item 011 Cat DH324NGK ...
Page 492: ......
Page 494: ......
Page 495: ...Item 013 Cat DH362FRK ...
Page 496: ......
Page 498: ......
Page 499: ...Item 015 Cat DH321NRK ...
Page 500: ......
Page 502: ......
Page 503: ...Item 017 Cat DH362FRK ...
Page 504: ......
Page 506: ......
Page 507: ...Itm 019 Cat DH221NGK ...
Page 508: ......
Page 510: ......
Page 511: ...Item 021 Cat DH361UGK ...
Page 512: ......
Page 513: ...TAB 6 Enclosed Control NEMA ...
Page 514: ......
Page 516: ......
Page 517: ...Instruction Data ...
Page 518: ......
Page 550: ......
Page 551: ......
Page 552: ......
Page 561: ......
Page 562: ......
Page 578: ......
Page 579: ...Drawings ...
Page 580: ......
Page 582: ......
Page 584: ......