Eaton Power Xpert 9395C UPS Installation and Operation Manual 164000821—Rev 06
3
•
X-Slot
®
Communication Bays.
Four communication bays are standard equipment. One to four optional X-
Slot
®
connectivity cards can be installed in the UPS module at any time. X-Slot cards are quickly installed at
the front of the UPS and are hot-pluggable. See
for additional information.
11..11..44
A
Addvvaanncceedd B
Baatttteerryy M
Maannaaggeem
meenntt
A three-stage charging system increases battery service life by optimizing recharge time, and protects batteries
from damage due to high current charging and inverter ripple currents. Charging at high currents can overheat
and damage batteries.
11..11..55
P
Poow
weerr M
Maannaaggeem
meenntt S
Sooffttw
waarree
Eaton’s Intelligent Power
®
Software solution, based on Web2.0 technology, includes two applications:
Intelligent Power
®
Manager
™
for UPS management and monitoring, and Intelligent Power
®
Protector
™
, which
allows graceful shutdown of operating systems. See
for additional information.
11..22
O
Oppttiioonnss aanndd A
Acccceessssoorriieess
Contact an Eaton sales representative for information about the following options.
11..22..11
IInntteeggrraatteedd B
Baatttteerryy C
Caabbiinneettss
Battery backup protection can be provided by equipping the UPS system with Eaton 9395C battery cabinets
containing sealed lead-acid, maintenance-free batteries. The cabinets are designed for standalone installation
and may be installed adjacent to the UPS or in a separate location. The recommended installation location for
adjacent battery cabinets is on the right side of the UPS cabinet to allow for future expansion using an external
module.
Consult the Eaton
®
Power Xpert
®
9395C Integrated Battery Cabinet (Models 1085 and 1085HR) Installation
Manual (TBD) for specifics on battery cabinet usage with the 9395C.
11..22..22
S
Syynncc C
Coonnttrrooll
An optional Eaton 9395C Sync Control maintains the critical load outputs of two separate single module 9395C
UPS systems in synchronization. This option facilitates the uninterrupted transfer of the load from one load bus
to another by means of transfer switches. The Sync Control is housed in a wall-mounted panel that can be
located between the UPS units for easy wiring.
11..22..33
S
Siinnggllee--FFeeeedd K
Kiitt
An optional kit is available for converting the dual-feed rectifier and bypass inputs to a single-feed configuration.
The kit consists of jumpers and bus bar extensions for each phase, and the hardware required for installation.
11..22..44
D
Diissttrriibbuutteedd B
Byyppaassss S
Syysstteem
m
The 9395C is based on UPS redundancy. Each UPS contains a UPM.
A distributed bypass UPS system with two to five UPSs can be installed to provide a capacity and/or redundant
system. This load sharing system provides more capacity than a single UPS, and can provide backup,
depending on the load and configuration. A Powerware Hot Sync Controller Area Network (CAN) Bridge Card
provides connectivity and operational mode control. The distributed bypass system consists of two to five
UPSs each with a parallel CAN card, and a customer-supplied tie cabinet or load distribution panel to act as a tie
point.
The tie cabinet is provided by the customer and must contain Module Output Breakers (MOBs) with dual
auxiliary contacts for control of the system.
11..22..55
C
Coonnttiinnuuoouuss S
Sttaattiicc S
Sw
wiittcchh
A continuous static switch is used to provide transfer of the load from the inverter to the bypass source in the
event the inverter become unavailable.