SINGAPORE
Tel : +65 6825 1684
Fax : +65 6825 1689
EatonSEA@eaton.com
INDONESIA
Tel : +62 21 522 6181
Fax : +62 21 522 6182
MALAYSIA
Tel : +603 7804 3618
Fax : +603 7803 6193
THAILAND
Tel : +662 946 6843
Fax : +662 519 0574
VIETNAM
Tel : +84 4 3936 5303
Fax : +84 4 3936 5307
Eaton is the trade name, trademark, and/
or service mark of Eaton Corporation or its
subsidiaries and affi liates.
® 2008 Eaton Corporation
All Rights Reserved
Printed in Singapore
July 2010
General
User interface
Graphical LCD with blue backlight and text in
English, French, German, Portuguese, Italian and
Spanish
LEDs
Four status-indicating LEDs
Topology
Double-conversion
Diagnostics
Full system self-test
UPS bypass
Automatic bypass
Dimensions
See models selection guide
Rail kit
Included with all units
Electrical Input
Nominal voltage
230V
220V-240V
user selectable
Voltage range
156–280 Vac (output PF 0.7)
Power draw of UPS
(full load)
6000VA: 26A @230V
Recommended input-
breaker rating
35A
Frequency
50/60 Hz autoselect
Frequency range
40–70 Hz
Electrical Output
Power factor
0.7
On utility voltage
±2% of nominal regulation
On battery voltage
±2% of nominal regulation
Efficiency
>97% in high-efficiency mode; 91% in normal mode
Frequency regulation
±3% Hz online
Load crest factor
3 to 1
Battery
Internal battery type
5.5Ah, sealed, lead-acid; maintenance free
Externa battery
modules
Up to four per 9135, rail kits included for rack
mounting
EBM battery type
5.5 Ah, sealed, lead-acid; maintenance free
Battery runtime
Four (4) minutes with internal batteries @100% load
(0.7 PF)
For additional details, see battery runtime chart
Battery recharge
time
Six (6) hours to recover 90 percent of nominal backup
time after 100 percent RCD load discharge
Battery replacement
Hot-swappable internal and external batteries
Start-on-battery
Allows start of UPS without utility input
Communications
Serial port
RS-232 standard, RS-232 cable provided
USB port
HID standard, for communicating with Windows XP/
Vista
Relay output
DB-9 Dry Contact-common alarm standard
Software
Intelligent Power Manager (IPM) and IPP
Optional
communication
cards
ConnectUPS-MS Network Management Card for direct
control and monitoring in SNMP-based ne works
ConnectUPS-MS Card with ModBus RTU interface
Serial Management Card-MS for integration to indus-
trial environment and building management systems,
remote shutdown for IBM AS/400 systems
Environmental
Safety markings
CE, GS
EMC
IEC/EN 62 040-2 class A
Audible noise
Max 46 dB
Ambient operating
0˚C to +40˚C
Storage temperature
-20˚C to +40˚C with batteries and
-25˚C to +55˚C without batteries
Relative humidity
5–90% non-condensing
In the interests of continual product improvement all specifications are subject to change without notice.
Eaton 9135 UPS
Product Focus
TECHNICAL SPECIFICATIONS
Heat Dissipation (BTUs/hr)
Operating mode
Efficiency
5 kVA
6 kVA
Normal
91%
1150
1350
Battery
86%
1650
1960
High efficiency
97%
370
450