 Web/SNMP Card (X and BD Models) Quick Start Instructions 164950185 Rev B

www.eaton.com/powerquality

3

Checklist

1.

Verify that all of the following items are available:

J

ConnectUPS Web/SNMP Card package contents (see
front cover)

J

Phillips screwdriver

J

Microsoft

R

 Windows

R

 operating system (for other operating

systems, see the help file on the Software Suite CD)

J

Available serial port (RS-232)

J

HyperTerminal

R

 (ships with Windows) or equivalent

terminal emulation application

J

Internet Explorer Web browser

2.

Contact your local network administrator for the following
mandatory network settings:

J

IP Address (static address

*

)

J

Gateway IP Address

J

Network Mask IP Address

*

If you are setting up the ConnectUPS Card in a DHCP

environment, the network administrator must set up the
DHCP server to provide a static address each time the card
makes a DHCP request. Provide the network administrator
with the card's MAC address (on the bottom of the card):

J

MAC address

3.

If you need e-mail functionality, obtain the following network
settings (either SMTP only or DNS and Host Name):

J

SMTP (mail server) IP Address

J

DNS (name server) IP Address

J

Host Name

Refer to the 

Connect

UP

S Web/SNMP Card User's Guide

PDF on the Software Suite CD for detailed setup information.

4.

List the applicable UPS load segment (receptacle group)
connections (refer to the UPS user's guide to see if load
segments are available for your UPS):

J

Load Segment 1 is connected to

J

Load Segment 2 is connected to

J

Load Segment 3 is connected to

Examples of load segment equipment connections are
“CPU MX1,” “Monitor MX1,” and “Router San Diego 1.”

Summary of Contents for Powerware Series

Page 1: ...Powerware Series Eaton ConnectUPS Web SNMP Card Quick Start Instructions X and BD Models...

Page 2: ...t Corporation HyperTerminal is a registered trademark of Hilgraeve Modbus is a registered trademark of Modicon IBM and AS 400 are registered trademarks of International Business Machines Inc All other...

Page 3: ...up the ConnectUPS Card in a DHCP environment the network administrator must set up the DHCP server to provide a static address each time the card makes a DHCP request Provide the network administrator...

Page 4: ...Eaton ConnectUPSt Web SNMP Card X and BD Models Quick Start Instructions 164950185Rev B www eaton com powerquality 4...

Page 5: ...ove the X Slott or BestDockt cover on the UPS rear panel Retain the screws NOTE If there is another card already installed with an attached communication cable disconnect the cable and then remove the...

Page 6: ...erTerminal 4 Select the appropriate serial connection such as COM1 See Figure 6 5 Set the serial line to 9600 baud No parity 8 data bits 1 stop bit and no flow control see Figure 7 6 Verify that the U...

Page 7: ...and 4 to set the Gateway Address and Network Mask 6 Change any other options as needed for your particular configuration by typing the corresponding number shown in the menu Each Configuration Menu se...

Page 8: ...se user guides for instructions Use the following procedure to install NetWatch software after you have installed and configured the card 1 Insert the Software Suite CD into the computer s CD ROM driv...

Page 9: ...wn your system see Figure 17 The default selection is recommended Select Next 11 The Event and Logging Options dialog opens see Figure 18 Select Next 12 Verify the configuration settings are correct a...

Page 10: ...Eaton ConnectUPSt Web SNMP Card X and BD Models Quick Start Instructions 164950185Rev B www eaton com powerquality 10...

Page 11: ......

Page 12: ...164950185B 164950185 B Eaton ConnectUPSt Web SNMP Card X and BD Models Quick Start Instructions 164950185 www eaton com powerq...

Reviews: