4 CANopen communication settings
4.7 Parameters
CANopen for DA1, DC1, DE11
09/16 MN040019EN
www.eaton.com
55
27DB
P00-13
Last Fault3 PDP seconds
ro
RUN
100
≙
100 s
U16
27DC
P00-13
Last Fault4 PDP hours
ro
RUN
100
≙
100 h
U16
27DD
P00-13
Last Fault4 PDP seconds
ro
RUN
100
≙
100 s
U16
2040
P00-14
t-HoursRun Enable hours
ro
RUN
100
≙
100 h
0h0m0s - 65535h59m59s
U16
2041
t-HoursRun Enable seconds
ro
RUN
100
≙
100 s
0h0m0s - 65535h59m59s
U16
27F4
P00-15
DC-Link0 Log 1
ro
RUN
230
≙
230 V
0 - 1200
U16
27F5
DC-Link0 Log 2
ro
RUN
230
≙
230 V
0 - 1200
U16
27F6
DC-Link0 Log 3
ro
RUN
230
≙
230 V
0 - 1200
U16
27F7
DC-Link0 Log 4
ro
RUN
230
≙
230 V
0 - 1200
U16
27F8
DC-Link0 Log 5
ro
RUN
230
≙
230 V
0 - 1200
U16
27F9
DC-Link0 Log 6
ro
RUN
230
≙
230 V
0 - 1200
U16
27FA
DC-Link0 Log 7
ro
RUN
230
≙
230 V
0 - 1200
U16
27FB
DC-Link0 Log 8
ro
RUN
230
≙
230 V
0 - 1200
U16
27FC
P00-16
Heatsink0 Log 1
ro
RUN
50
≙
50°C
-10 - 150
S16
27FD
Heatsink0 Log 2
ro
RUN
50
≙
50°C
-10 - 150
S16
27FE
Heatsink0 Log 3
ro
RUN
50
≙
50°C
-10 - 150
S16
27FF
Heatsink0 Log 4
ro
RUN
50
≙
50°C
-10 - 150
S16
2800
Heatsink0 Log 5
ro
RUN
50
≙
50°C
-10 - 150
S16
2801
Heatsink0 Log 6
ro
RUN
50
≙
50°C
-10 - 150
S16
2802
Heatsink0 Log 7
ro
RUN
50
≙
50°C
-10 - 150
S16
2803
Heatsink0 Log 8
ro
RUN
50
≙
50°C
-10 - 150
S16
2804
P00-17
MotorCurrent0 Log 1
ro
RUN
100
≙
10.0 A
U16
2805
MotorCurrent0 Log 2
ro
RUN
100
≙
10.0 A
U16
2806
MotorCurrent0 Log 3
ro
RUN
100
≙
10.0 A
U16
2807
MotorCurrent0 Log 4
ro
RUN
100
≙
10.0 A
U16
2808
MotorCurrent0 Log 5
ro
RUN
100
≙
10.0 A
U16
2809
MotorCurrent0 Log 6
ro
RUN
100
≙
10.0 A
U16
280A
MotorCurrent0 Log 7
ro
RUN
100
≙
10.0 A
U16
280B
MotorCurrent0 Log 8
ro
RUN
100
≙
10.0 A
U16
280C
P00-18
DC-Link V-Ripple0 Log
ro
RUN
1
≙
1 V
U16
280D
DC-Link V-Ripple0 Log
ro
RUN
1
≙
1 V
U16
280E
DC-Link V-Ripple0 Log
ro
RUN
1
≙
1 V
U16
280F
DC-Link V-Ripple0 Log
ro
RUN
1
≙
1 V
U16
2810
DC-Link V-Ripple0 Log
ro
RUN
1
≙
1 V
U16
2811
DC-Link V-Ripple0 Log
ro
RUN
1
≙
1 V
U16
2812
DC-Link V-Ripple0 Log
ro
RUN
1
≙
1 V
U16
2813
DC-Link V-Ripple0 Log
ro
RUN
1
≙
1 V
U16