4 CANopen communication settings
4.7 Parameters
CANopen for DA1, DC1, DE11
09/16 MN040019EN
www.eaton.com
59
2086
P-34
PDP-Address
rw
RUN
1
≙
1
1 - 63
U16
2087
P-35
RS485-0 Baudrate
rw
RUN
1
≙
1
0 - 4
U16
2088
P-36
Comm Timeout Modbus RTU
rw
RUN
1
≙
1
0 - 8
U16
2089
P-37
Parameter Set
rw
STOP
1
≙
1
0 - 1
U16
208A
P-38
Password Level2
rw
RUN
1
≙
1
0 - 9999
U16
208B
P-39
Parameter Lock
rw
RUN
1
≙
1
0 - 1
U16
208C
P-40
Action@Communication
Loss
rw
STOP
1
≙
1
0 - 4
U16
208D
P-41
ParameterAccess
rw
RUN
1
≙
1
0 - 1
U16
2096
P-50
CAN0 Baudrate
rw
RUN
1
≙
1
0 - 3
U16
2097
P-51
RO1 Function
rw
RUN
1
≙
1
0 - 9
U16
2098
P-52
RO1 upper Limit
rw
RUN
100
≙
10.0 %
0 -2000
U16
2099
P-53
RO1 Switch-On Delay
rw
RUN
10
≙
1.0 s
0 - 250
U16
209A
P-54
RO1 Hysteresis
rw
RUN
100
≙
10 %
0 - 1000
U16
CANOpen
Index [hex]
Para
meter
Designation
Access
Scale
Value range
Data
format
rw/
ro
RUN/
STOP
Summary of Contents for PowerXL DA1