5 Application example – CANopen fieldbus connection on DA1 variable frequency drives
5.2 Materials required
CANopen for DA1, DC1, DE11
09/16 MN040019EN
www.eaton.com
67
A new node called
DA1 (EDS) [VAR]
will be added underneath the
CanMaster[Var]
node.
Adjusting the CAN parameters
Now configure the CAN-specific parameters for the DA1 variable frequency
drive:
▶
Click on the
DA1 (EDS) [VAR]
node and open the
CAN parameters
tab.
▶
Enable the
Nodeguarding
checkbox.
▶
Now open the
Send PDO-Mapping
tab.
Modify the properties for the
PDO 0x1800
and
PDO 0x1801
objects as
specified below:
▶
Select the
PDO 0x1800
object on the right pane and click on the
Properties
button.
→
The
Node ID
must be identical to the DA1 variable frequency
drive address set with parameter P5-01.
Nodeguarding
must be enabled in order to be able to detect
communication faults.