4 CANopen communication settings
4.5 Object directory
36
CANopen for DA1, DC1, DE11
09/16 MN040019EN
www.eaton.com
4.5.9 Manufacturer-specific objects on DC1…E1 devices
Table 18: Manufacturer-specific objects
Index
[hex]
Object Name
Access
rw/ro
Scaling
value range
Data
format
description
2000
Control word
rw
U16
Command
2001
Frequency reference value
rw
500
≙
50.0 Hz
-5000 - 5000
S16
Frequency
reference value
2002
Ramp Time
rw
500
≙
5.00 s
0 - 60000
U16
User ramp time
2004
High Resolution Frequency reference
value
rw
3000
≙
50.0 Hz
-30000 - 30000
S16
Frequency
reference value
(high-resolution)
200 A
Error code / Drive Status
ro
U16
status word
200B
Output Frequency
ro
500
≙
50.0 Hz
0 - 5000
S16
Actual value in
Hertz (Hz)
200D
Motor current
ro
100 = 10.0 A
U16
Motor Current
200E
Motor Torque
ro
500
≙
50.0 %
0 - 2000
S16
Motor Torque
200F
Motor Power
ro
100 = 1.00 kW
U16
Instance Motor
Power
2015
Analog Output %
ro
500
≙
50.0 %
0 - 1000
U16
Analog output as
a %
2017
Relay Output Status
ro
1
≙
1
0 - 1
U16
Relay output 1
2043
Control Board Temperature
ro
50
≙
50 °C
-10 - 150
S16
Control board
temperature
2044
Speed Reference (Internal Format)
ro
3000
≙
50.0 Hz
0.00 - P-01
U16
Internal frequency
reference value
2046
Digital Pot / Keypad reference
ro
3000
≙
50.0 Hz
0.00 - P-01
U16
Keypad frequency
reference value
23E8
Scope index 12
rw
23E9
Scope index 34
rw
Summary of Contents for PowerXL DA1
Page 4: ...II ...