Appendix B—Installation Guidelines
DG1 Series VFD
MN040002EN—March 2014
www.eaton.com
51
Table 34. 230V Temperature and Switching Frequency Deratings (CT)
Note
1
FR6 available in 2015.
Constant Torque
(CT) /High
Overload (IH)
Frame
Size
Percentage of Rated Current
Switching Frequency
Temperature
1 kHz
2 kHz
3 kHz
3.6 kHz
4 kHz
5 kHz
6 kHz
7 kHz
8 kHz
9 kHz
10 kHz
12 kHz
40°C
FR1
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
95.9%
91.8%
FR2
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
FR3
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
FR4
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
96.2%
92.3%
88.5%
—
FR5
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
96.1%
92.2%
88.2%
—
FR6
1
1
1
1
1
1
1
1
1
1
1
—
50°C
FR1
100.0%
100.0%
100.0%
100.0%
100.0%
97.7%
95.5%
91.8%
88.2%
84.5%
79.1%
73.6%
FR2
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
98.0%
96.0%
94.0%
91.0%
88.0%
FR3
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
100.0%
FR4
100.0%
100.0%
100.0%
100.0%
97.1%
94.3%
91.4%
88.5%
84.7%
80.8%
77.0%
—
FR5
100.0%
100.0%
100.0%
100.0%
95.1%
90.3%
85.4%
80.6%
74.5%
68.4%
62.4%
—
FR6
1
1
1
1
1
1
1
1
1
1
1
—
60°C
FR1
83.6%
83.6%
83.6%
83.6%
83.6%
80.9%
78.2%
75.5%
72.7%
70.0%
65.9%
61.8%
FR2
92.0%
92.0%
92.0%
92.0%
92.0%
92.0%
92.0%
130.0%
168.0%
80.0%
101.3%
68.0%
FR3
91.7%
91.7%
91.7%
91.7%
91.7%
90.6%
89.6%
88.5%
87.5%
86.1%
84.7%
83.3%
FR4
83.9%
83.9%
83.9%
83.9%
80.7%
77.6%
74.4%
71.3%
67.4%
63.6%
59.8%
—
FR5
79.4%
79.4%
79.4%
79.4%
75.6%
71.8%
67.9%
64.1%
59.5%
54.9%
50.3%
—
FR6
1
1
1
1
1
1
1
1
1
1
1
—
Summary of Contents for PowerXL DG1-323D7FB-C21C
Page 1: ...PowerXL DG1 Series VFD Installation Manual Effective March 2014 New Information...
Page 2: ......
Page 83: ......