Troubleshooting
◗
The battery backup outlets
8
are not supplied with power.
◗
The connected devices are not
supplied when AC power fails.
◗
AC power is available, but the
UPS
operates on battery power.
◗
The filtered outlets
7
are not
supplied.
◗
Green button
11
flashes
frequently and audio alarm beeps
every 5 secondes.
◗
Green button
11
flashes
frequently and audio alarm is
continuous.
◗
Red LED
10
is on and the
audio alarm beeps every 30
seconds.
◗
Green LED
9
is off and the
filtered outlets
7
are supplied.
◗
The telephone line is disturbed
or modem access is not possible.
◗
Red LED
10
is ON.
Problem
Diagnostic
Solution
◗
Button
11
is not pressed.
◗
The devices are not connected to
the battery backup outlets
8
.
◗
Circuit breaker
12
has been tripped
by an overload on the
UPS
output.
◗
The wall outlet is not supplied.
◗
Circuit breaker
12
has been tripped
by an overload on the
UPS
output.
◗
The
UPS
frequently operates on
battery power because the AC power
source is of poor quality.
◗
The
UPS
battery backup outlets
8
are overloaded.
◗
A fault has occurred on the
UPS
.
The battery backup outlets
8
are no
longer supplied.
◗
Surge protection is no longer
provided.
◗
Surge protection on the telephone
line is no longer provided.
◗
The battery has reached the end of
its service life.
◗
Press button
11
and check that it
turns green.
◗
Connect the devices to the battery
backup outlets
8
.
◗
Disconnect excess equipment and
reset the circuit breaker
12
by pressing
the corresponding button.
◗
Supply power to the wall outlet.
◗
Disconnect excess equipment and
reset the circuit breaker
12
by pressing
the corresponding button.
◗
Have the electrical installation
checked by a professional or use
another wall outlet.
◗
Disconnect excess equipment
connected to the battery backup outlets
8
.
◗
Call after-sales support.
◗
Call after-sales support.
◗
Disconnect the telephone line from
the wall outlet.
◗
Call after-sales support.
◗
Have the battery replaced.
1
2
3
4
5
6
7
8
9
10
Advanced customizing of your UPS:
Sensitivity to variations of the AC power supply
◗
Only to be used
if frequent switching to the
UPS
battery
due to large variations in the AC supply voltage.
◗
Accessing the programming mode: with the device
switched off, press button
11
for 6 s and release it once
LEDs
10 11
9
have come on.
◗
Display of the 3 possible voltage ranges according to the
status of LEDs
10
and
11
:
Audio alarm
◗
Possibility of deactivating the audio alarm when the
UPS
is operating on the battery.
◗
Accessing the programming mode: with the device
switched off, press button
11
for 11 s and release it once
the audio alarm sounds.
◗
Display of the 2 possible audio alarm modes:
Normal mode
(factory
configuration):
AC supply
between 184V
and 264V
Low range
mode:
AC supply
between
160V
and 264V
Low and high
range mode:
AC supply
between
160V
and
284V
◗
Memorizing the mode: 10 s after the last press of the
button.
◗
Memorizing the mode: 10 s after the last press of the
button.
Normal mode (factory
configuration):
the
UPS
emits a beep every
10 s when operating on its
battery.
Silent mode:
the
UPS
emits a single
beep when switching to
battery operation and then
remains silent.
10
11
9
10
11
9
10 = ON 11 = OFF 10 = OFF 11 = ON
10 = ON 11 = ON
10
11
9
Normal mode
activated:
Buzzer emits long
beep.
Silent mode
activated:
Buzzer emits
short beep.
Change from one mode to another by
successively pressing button
11
.
Change from one mode to another by
successively pressing button
11
.