WIRING

1.  Pull field wiring into cover module.

2.  Close all unused conduit entries with conduit 

plugs provided.  To prevent galling and to ensure 

water-tightness, lubricate conduit plugs with 

Crouse-Hinds HTL lubricant before installing, and secure 

wrench-tight with at least five (5) full threads engaged 

(42-52 ft.-lb. for 3/4” plugs, and 58-68 ft.-lb. for 1” plugs). 

3.  Hang LED luminaire on the cover module hinge hook.  

See Figure 2a.

4.  Connect supply wires to luminaire wire leads or terminal 

block per the attached wiring diagrams using methods 

that comply with all applicable codes.  See Figure 2b.  

Tighten all electrical connections.

5.  Close driver housing onto cover module, making sure 

that all wires are safely 

inside driver housing.  

Tighten captive closing 

screw to 30 in.-lbs. (3.4 

N-m). Ensure two (2) 

bosses on driver housing 

are in contact with cover 

module.

6.  Turn power on.

FIGURE 2a

INSTALLATION

MOUNTING

1.  Mount the cover module in its support position.
•  Ceiling and wall mount: mark and drill desired location 

on mounting surface.  Secure with 1/4” (6mm) bolts 

or lag screws (not provided).

•  Pendant, stanchion mount: securely thread onto the 

appropriate NPT size conduit.  Tighten set screw 

located in the conduit hub.  See Figure 1.

•  Crouse-Hinds HTL thread lubricant must be added to 

the conduit threads to prevent water from entering 

the fixture.

IF 1628 • 05/22 

                         Copyright © 2022, Eaton’s Crouse-Hinds Division   

Page 1

Pro-Champ LED Luminaires

PVM Series Industrial LED Lighting

Installation & Maintenance Information

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

IF 1628

WARNING

To avoid the risk of fire, explosion or electric 

shock,

 this product should be installed, inspected 

and maintained by a qualified electrician only, in 

accordance with all applicable electrical codes.

WARNING

To avoid electric shock:

•  Be certain electrical power is OFF before and during 

installation and maintenance.

•  Luminaire must be supplied by a wiring system for 

the specific hazardous locations suitable per local 

code with an equipment grounding conductor.

To avoid burning hands:

•  Make sure LEDs and drivers are cool to touch when 

performing maintenance.  

Set-screw

Open 

Hinge

Ground Wires

FIGURE 1

APPLICATION

Luminaire construction is designed for use indoors and 

outdoors in marine and wet locations, where moisture, dirt, 

corrosion, vibration, and rough usage may be present.

•  Wet location, Type 4X

•  UL1598 Luminaires, UL1598A Marine

•  IP66

•  cUL

FIGURE 2b

IF 1628 • 05/22 

                         Copyright © 2022, Eaton’s Crouse-Hinds Division 

Page 2

PVM supplied with a choice of voltages:

•  100-277VAC 50/60 Hz

•  108-250VDC

•  347V

•  480V

TRANSFORMER

GROUND

PE

LINE

VOLTAGE

N

COM

347/480 V

L1

GND (SEE NOTE 4 SHT 1)

GRN

GRN

ACL(BLK)

ACN(WHT)

GND (SEE NOTE 4 SHT 1)

COM

WHT

BLK

INPUT

ACN(WHT)

ACL(BLK)

GRN

WHT

190/270 V

BLK

INPUT

DRIVER # 2

OUTPUT

V-(BLK)

V+(RED)

V-(BLK)

DRIVER # 1

OUTPUT

V+(RED)

GROUND

LINE

VOLTAGE

PE

N

L1

GND 

GRN

GRN

ACL(BLK)

ACN(WHT)

WHT

BLK

INPUT

DRIVER

V+(RED)

OUTPUT

V-(BLK)

BLK

RED

DENOTES CONNECTION

CLOSED END CRIMP CONNECTOR

 PER BOM

DENOTES WIRE CROSS

OVER, NOT CONNECTION POINT

RED or PURPLE

BLK

BLK

BLK

RED

BLK

RED or PURPLE

RED

PVM9L

PVM7L

PVM5L

PVM3L

BLK

RED

PVM3L

N

PE

L1

BLK

V-(BLK)

ACN(WHT)

WHT

DRIVER

GRN

(GND) 

ACL(BLK)

ACN(WHT)

(GND) 

GRN

WHT

BLK

GRN

INPUT

V+(RED)

V-(BLK)

OUTPUT

RED or PURPLE

BLK

DRIVER

ACL(BLK)

BLK

INPUT

V+(RED)

OUTPUT

RED or PURPLE

BLK

RED

BLK

PVMV9L

PVM7L

PVM5L

RED

GROUND

VOLTAGE

LINE

5L, 7L & 9L

WIRING DIAGRAM FOR:

DIAGRAM #1:

PVM3L SERIES

WIRING DIAGRAM FOR:

DIAGRAM #2:

347 OR 480 VOLT TRANSFORMER

WIRING DIAGRAM FOR:

DIAGRAM #3:

PE

COM

COM

190/270 V

347/480 V

TRANSFORMER

ACL(BLK)

ACN(WHT)

V+(GREY)

OUTPUT

V-(BLK)

INPUT

V-(BLK)

V+(GREY)

OUTPUT

BLK

BLK

RED

RED

WHT

BLK

DRIVER # 2

DRIVER # 1

ACL(BLK)

INPUT

ACN(WHT)

BLK

WHT

LINE

VOLTAGE

N

PVM11L

BLK

GREY

BLK

GREY

GROUND

L1

GREY

BLK

ACN(WHT)

INPUT

ACL(BLK)

DRIVER # 3

BLK

WHT

V+(GREY)

V-(BLK)

OUTPUT

GRN

BLK

RED

347 OR 480 VOLT TRANSFORMER

WIRING DIAGRAM FOR:

DIAGRAM #4:

ON PVM11L

NOTE:  Ground wire must be added to mounting plate

ground lug and to lugs on entry hubs.  Ground wire included.

Directive EU 2019/2022

This product contains a light source of energy efficiency 
class D or E.

WARNING

To avoid explosion:

•  Make sure the supply voltage is the same as the 

rated luminaire voltage.

•  Do not install where the marked operating 

temperatures exceed the ignition temperature of the 

hazardous atmosphere.

•  Do not operate in ambient temperatures above those 

indicated on the luminaire nameplate.

•  Use only replacement parts from Crouse-Hinds.

•  Use proper supply wiring as specified on the 

luminaire nameplate.

•  All surfaces must be clean. 

•  Before opening wiring compartment, electrical power 

to the luminaire must be turned off and area must be 

free from hazardous atmosphere.  Keep tightly closed 

when in operation.

•  To minimize the risk from electrostatic discharge, 

when cleaning, wipe the lens with a clean, damp 

cloth.

•  LED compartment is non serviceable. Do not open.