7
Instructional Leaflet
IB2C12063H03
Effective March 2012
Instructions for Installation, Operation and
Maintenance of Magnum SB Insulated Case
Low Voltage Power Circuit Breakers
EATON CORPORATION
www.eaton.com
Table 1. Magnum SB Ratings
Max
Amps
Breaker
Designation
Interrupting Rating (kA)
@
635v. 508v. 254v.
Short
Time
Rating (kA)
Fixed
Instantaneous
Non-Adjustable
Trip Setting
800
SBN-508
35 50 50
20
18 X In
j
800
SBN-608
42 65 65
20
18 X In
j
800
SBN-C08
65 100 100
20
18 X In
j
800
SBS-608
65 65 65
20
18 X In
j
800
SBS-C08
85 100 100
20
18 X In
j
1200
SBN-512
35 50 50
25
18 X In
j
1200
SBN-612
42 65 65
25
18 X In
j
1200
SBN-C12
65 100 100
25
18 X In
j
1200
SBS-612
65 65 65
25
18 X In
j
1200
SBS-C12
85 100 100
25
18 X In
j
1200
SBS-E12
- 150 200
30
30kA
1600
SBN-516
35 50 50
30
18 X In
j
1600
SBN-616
42 65 65
30
18 X In
j
1600
SBN-C16
65 100 100
30
18 X In
j
1600
SBS-616
65 65 65
30
18 X In
j
1600
SBS-C16
85 100 100
30
18 X In
j
1600
SBS-E16
- 150 200
30
30kA
2000
SBN-620
65 65 65
35
18 X In
j
2000
SBN-C20
65 100 100
35
18 X In
j
2000
SBS-620
65 65 65
35
18 X In
j
2000
SBS-C20
85 100 100
35
18 X In
j
2000
SBS-E20
- 150 200
30
30kA
2500
SBS-625
65 65 65
45
18 X In
j
2500
SBS-C25
85 100 100
45
18 X In
j
2500
SBS-E25
- 150 200
50
50kA
3000
SBS-630
65 65 65
50
18 X In
j
3000
SBS-C30
85 100 100
50
18 X In
j
3000
SBS-E30
- 150 200
50
50kA
4000
SBS-840
85 100 100
72
18 X In
j
4000
SBS-C40
100 100 100
72
18 X In
j
4000
SBS-E40
- 150 200
50
50kA
4000
SBN-840
65 85 85
72
k
18 X In
j
4000
SBN-C40
65 100 100
72
k
18 X In
j
5000
SBS-850
85 85 85
85
18 X In
j
5000
SBS-C50
100 100 100
90
18 X In
j
5000
SBS-E50
- 150 200
50
50kA
j
In is defined by the current sensor and rating plug combination
k
Short Time Rating at 635v is 65kA
A . Low voltage power circuit breaker family name
B . Breaker family designation number
C . Breaker frame size in amperes
D . Interrupting capacity rating
E . Factory Equipped Accessories
Figure 2. Typical Magnum SB Nameplate
WARNING
MAGNUM SB CIRCUIT BREAKERS ARE ROBUST AND ARE PROVIDED
WITH SAFETY FEATURES. NEVERTHELESS, THE VOLTAGES,
CURRENTS AND POWER LEVELS AVAILABLE IN AND AROUND
THIS EQUIPMENT WHEN IT IS IN OPERATION ARE EXTREMELY
DANGEROUS AND COULD BE FATAL. UNDER NO CIRCUMSTANCES
SHOULD INTERLOCKS AND OTHER SAFETY FEATURES BE MADE
INOPERATIVE, AS THIS MAY RESULT IN DEATH, BODILY INJURY OR
PROPERTY DAMAGE.
Safety Practices
To protect personnel associated with the installation, operation
and maintenance of this equipment, the following practices
must be followed: