background image

Eaton Lighting Systems                                                             iLight Product Series - SCD24       IM7524      iss 4                   5

Network Termination

Network Connections

IMPORTANT NOTE: Connecting a mains potential cable to the iLight Network terminals is likley 
to damage the unit and others connected, and invalidate warranty.

Termination On = Jumper across upper pins

Termination Off = Jumper across lower pins

IMPORTANT: Ensure jumper is in the off 

position for all devices other than those at the 

the end-of-line.

Applies 120Ω resistor to the iCAN network. 
Required at each end of the network cable run 
only.

Function

Network Cable Colour

0V

Black

CAN L

White

Shield

Silver

CAN H

Blue

+12Vdc

Red

Connections for the iCAN network are located on the CPU card at the bottom of the unit with 

the cover removed. 

There are two 5-way green connectors for the network. Either of 

these may be used (as an in and an out) or a single used with the 

network cable doubled-up to it. 

Summary of Contents for SCD24

Page 1: ...SCD24 24 Channel DMX Source Controller Installation guide...

Page 2: ...iLight Product Series SCD24 IM7524 iss 4 2 Contents Introduction 3 Dimensions 3 Technical Data 3 Mounting 4 DMX Connections 4 Connecting to the Mains 4 Network Connections 5 NetworkTermination 5 Servi...

Page 3: ...controlled like any other iLight Source Controller using any of the iLight user interfaces to activate scenes and sequences Dimensions Specification Electrical Supply 230 volts 10 50 60 Hz 1 Amp optio...

Page 4: ...0mm above and below the unit if trunking with a depth greater than 50mm is used Connecting Mains Supply This unit requires a nominal 230V single phase supply Live Neutral and Earth with 1A capability...

Page 5: ...ORTANT Ensure jumper is in the off position for all devices other than those at the the end of line Applies 120 resistor to the iCAN network Required at each end of the network cable run only Function...

Page 6: ...ork The LEDs indicate the following Normal operation Steady green LED blinking 1 x per second Red LED off Message transmission and receipt indicated by red LED flashing for duration of data transmissi...

Page 7: ...s should this be suspected When the Source Controller is placed into override mode it will no longer respond to commands sent over the iCAN network Override mode can also be used to restore power to o...

Page 8: ...to and perform in accordance with Seller s written specifications For detailed warranty information contact Eaton Lighting Systems This warranty will be limited to the repair or replacement at Seller...

Reviews: