Page 6 

 

Connection Details 

TR 

The TR terminal provides the control unit 
with the tamper status of the siren. TR is 
activated (and the siren self-activates) if 
any of the following occurs: 

a)  The siren's tamper switch is activated. 

b)  The BELL input from the control 

unit/expander is cut, providing the Trig 
Mon link (page 7) is fitted (SDR-WEXT-
G3 only).  

c)  Power from the control unit/expander is 

disconnected. 

When using the SDR-WEXT-G2, TR is 0V 
in normal operation, and switched to open 
circuit when a tamper is detected. 

When using the SDR-WEXT-G3, the 
voltage and termination of the TR terminal 
must be configured using the Tmp Feed 
jumper (see page 8). 

ENG (Installer Mode) 

Setting the ENG input to 0V sets the siren 
in installer (engineer) mode. You should 
normally connect ENG to a control 
unit/expander output configured as type 
"Installer on Site", which activates when 
entering the Installer menu at a keypad and 
deactivates when exiting the Installer menu 
(at every keypad). 

Installer mode prevents the sounder and 
strobe from activating when the lid is 
opened. 

When installer mode is activated, both 
comfort LEDs switch on continuously for a 
few minutes. 

STR and BELL 

0V at the STR (strobe) input activates the 
strobe. 0V at the BELL (trigger) input 
activates the sounder. Some control units 
provided dedicated  strobe and bell outputs. 
If not (or an expander is used), connect to 

outputs of type "Strobe" and "Siren" 
respectively. 

F-F and F-R and RST 

The SDR-WEXT-G3 provides F-F (Fault 
Feed) and F-R (Fault Return) volt-free 
terminals, which are used to provide 
sounder and battery fault reporting to the 
control unit.  

To enable sounder and battery fault 
reporting, see

 Quick Reference 

on page 4 

for connection and configuration details. 

Technical Detail for Advanced Installers 

The siren tests the battery voltage under 
load conditions every hour and when the 
ENG input is deactivated. The sounder is 
tested each time it is activated. Under 
normal conditions, F-F and F-R are closed 
circuit. If either test fails, F-F and F-R go 
open circuit, which causes the control unit 
to generate an alarm. The contacts remain 
open circuit until the test is successful or 
the siren's tamper switch is activated (in the 
latter case, the siren assumes that an 
engineer is fixing the problem). 

A sounder or battery fault may prevent the 
system from being set (depending on 
grade) and cannot be cleared until the 
siren's tamper switch is activated, or the 
test is performed again and passes. 

You can start a test manually by using the 

Installer Menu 

– Test – Sirens & Sounders 

– Wired Sirens – Remote Self-Test

 

, which 

tests both the sounder and battery. 

When 

Remote Self-Test

 

is used, the RST 

(Remote Self-Test) input is set to 0V for the 
duration of the test. This causes F-F and F-
R momentarily to go open circuit, which 
confirms to the control unit that the siren is 
healthy. If the siren passes, F-F and F-R go 
closed circuit (normal state) within 60 
seconds. The siren fails the test if the 
contacts remain open after 60 seconds or if 
the control unit does not detect the open 
circuit at the start of the test. 

A remote self-test occurs only when RST is 
0V; setting RST to 12V or leaving it 
unconnected disables remote self-test. 

Summary of Contents for SDR-WEXT

Page 1: ...to install 100 dB A sound output High power comfort LEDs High power LED strobes Selectable SCB or SAB mode Built in spirit level Self supporting lid for ease of installation Revolving fixing holes En...

Page 2: ...Reference on page 4 Step 4 Disconnect all Power Make sure that all power to the control unit is disconnected including the backup battery Also make sure that the battery in the siren is not connected...

Page 3: ...are using an i on or Menvier control unit you need to carry out the following for the siren a If you are using the ENG input Installer Menu Outputs Radio Wired Outputs Panel Exp nn nn output number Ty...

Page 4: ...to enable the comfort LEDs Time Choose the sounder cut off period 0V 12V BELL Trigger or output of type Siren STB STR or output of type Strobe Output of type Installer on Site Output of type Remote Se...

Page 5: ...BELL Aux B Aux B ADE T STROBE B D A Texecom C S B A D GE 270R TR STROBE EXT BELL BELL 12V BHO Risco Gardtec SCBP STB BELL BELL SCBA DSC Range ZONE PSM1 BELL BELL AUX Table 1 Connections to Other Contr...

Page 6: ...Return volt free terminals which are used to provide sounder and battery fault reporting to the control unit To enable sounder and battery fault reporting see Quick Reference on page 4 for connection...

Page 7: ...using an open collector output from another type of control unit and want to check for the presence of a 4k7 pull up temporarily connect a separate 4k7 resistor between the output and 0V if a 4k7 res...

Page 8: ...onitoring The siren monitors the following Tamper conditions All tamper conditions reported by the TR terminal see page 6 are continuously monitored The siren self activates on a tamper Battery voltag...

Page 9: ...nal Current Consumption 35mA quiescent current including battery charge and comfort LEDs 225mA in alarm current in SAB mode Sound Output 100 dB A IP Rating IP65 Strobe Frequency Double flash approx 1H...

Page 10: ...Page 10 NOTES...

Page 11: ...Page 11 NOTES...

Page 12: ...ONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no event will Eaton be responsible to the purchaser or user in contract in tort including negligence str...

Reviews: