Cable Recommendations 

Standard 7/0.2 un-screened alarm cable 
should be used. 

The maximum recommended cable 
distance is 50m if you are using SAB mode 
and only TR for tamper monitoring (i.e. not 
both TR and TF). This can be increased to 
100m by doubling the 0V cores. 

The maximum recommended cable 
distance is 100m if you are using SCB 
mode, or both TR and TF for tamper 
monitoring. 

Specifications 

Type of Warning Device:

 External, 

remote-powered 

Supply Voltage:

 12-15V dc, 13.7V dc 

(nominal) 

Current Consumption:

 35mA quiescent 

current including battery charge and 
comfort LEDs. 225mA in-alarm current 
(in SAB mode) 

Sound Output: 

100 dB(A) 

IP Rating: 

IP65 

Strobe Frequency: 

Double-flash @ approx 1Hz 

Case Material: 

Polycarbonate 

Intrusion Standards: 

PD6662:2010,  

EN 50131-4:2009 

Certification Body: 

ANPI 

EN 50131-4 Grade: 

Grade 2 (SDR-WEXT-

G2), or Grade 3 (SDR-WEXT-G3) 

Environmental Class:

 Class IV 

Standby Battery Type:

 6x1.2V 240Ah 

Nickel Metal Hydride; part number for 
replacement batteries is SDR-W-BAT2 

Battery Life:

 Typically 5 years 

Low Battery Warning (grade 3):

 6.25V 

Response to Loss of Remote Power:

 

Activate sounder 

Response to Loss of Trigger 

Connectivity:

 Activate sounder (grade 

3) 

Weight: 

1.2kg 

Operating Temperature Range: 

-25°C to 

+60°C 

Max Relative Humidity: 

95% 

Dimensions: 

290mm (h) x 277mm (w) x 

80mm (d) 

 

 

 

Summary of Contents for SDR-WEXT

Page 1: ...to install 100 dB A sound output High power comfort LEDs High power LED strobes Selectable SCB or SAB mode Built in spirit level Self supporting lid for ease of installation Revolving fixing holes En...

Page 2: ...Reference on page 4 Step 4 Disconnect all Power Make sure that all power to the control unit is disconnected including the backup battery Also make sure that the battery in the siren is not connected...

Page 3: ...are using an i on or Menvier control unit you need to carry out the following for the siren a If you are using the ENG input Installer Menu Outputs Radio Wired Outputs Panel Exp nn nn output number Ty...

Page 4: ...to enable the comfort LEDs Time Choose the sounder cut off period 0V 12V BELL Trigger or output of type Siren STB STR or output of type Strobe Output of type Installer on Site Output of type Remote Se...

Page 5: ...BELL Aux B Aux B ADE T STROBE B D A Texecom C S B A D GE 270R TR STROBE EXT BELL BELL 12V BHO Risco Gardtec SCBP STB BELL BELL SCBA DSC Range ZONE PSM1 BELL BELL AUX Table 1 Connections to Other Contr...

Page 6: ...Return volt free terminals which are used to provide sounder and battery fault reporting to the control unit To enable sounder and battery fault reporting see Quick Reference on page 4 for connection...

Page 7: ...using an open collector output from another type of control unit and want to check for the presence of a 4k7 pull up temporarily connect a separate 4k7 resistor between the output and 0V if a 4k7 res...

Page 8: ...onitoring The siren monitors the following Tamper conditions All tamper conditions reported by the TR terminal see page 6 are continuously monitored The siren self activates on a tamper Battery voltag...

Page 9: ...nal Current Consumption 35mA quiescent current including battery charge and comfort LEDs 225mA in alarm current in SAB mode Sound Output 100 dB A IP Rating IP65 Strobe Frequency Double flash approx 1H...

Page 10: ...Page 10 NOTES...

Page 11: ...Page 11 NOTES...

Page 12: ...ONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no event will Eaton be responsible to the purchaser or user in contract in tort including negligence str...

Reviews: