3. Save SHC Configuration in original MRF Project 

Note!:

 The original MRF project is the MRF project which is currently active for the 

configuration. Normally this project is created during the initial installation of the SHC and 
maintained after that.  

Follow the next steps to synchronize the SHC configuration with the original used MRF Project. 
The configuration includes Zones, devices, Macros, Planner programs, Cameras and System 
configurations, etc. 

1.  Export the SHC Configuration (Always keep this file to be able to restore the SHC 

configuration). 

2.  Open the original used MRF Project for your SHC in the new 

MRF V2.42 

or higher. 

3.  Right-click on the Smart Home Controller and select: 

Scan Device new

 

(Only necessary if RF-Module firmware has been updated as well). 

4.  Right-click on the SHC Icon and select: 

Settings

 

5.  Navigate to 

Devices & Zones

 and click: 

Import Configuration

 

6.  Select the just exported SHC Configuration file (step 1) and click: 

Open

 

7.  The SHC configuration is imported and you should see the zones and changes in 

device names and functions. 

8.  Click OK and Save the MRF Project. The SHC Configuration is now in synch with the 

MRF project.  

Remark: Use now the MRF Project to make changes to SHC Zones and Device 
configurations, export it and import it into the SHC.

 

 

 

 

Summary of Contents for Smart Home Controller 2.0

Page 1: ...Release 2 0 x version 1 3 Smart Home Controller 2 0 Quick Installation Manual with MRF...

Page 2: ...ve SHC Configuration in original MRF Project 16 4 Troubleshooting 17 4 1 First check Most important 17 4 2 Basic Health check 17 4 3 LED Indicators on the Smart Home Controller Box 18 4 4 How to resto...

Page 3: ...Quick Installation Manual with MRF Page 3 of 24 Appendix B Feedback form 24...

Page 4: ...t this document This manual is intended for trained Installers only and describes the quick installation and configuration of new Smart Home Controller 2 x projects with MRF Following this manual will...

Page 5: ...Avoid disturbance from other equipment like WiFi routers Minimum distance 0 5m Installation steps 1 Use the mounting holes in the SHC to screw the SHC to the wall 2 Connect the SHC to your home netwo...

Page 6: ...ic Use the new generation Actuators with Extended Status Messaging support to increase the status reliability at hot spots MRF Project installation steps 1 Create the Project topology Insert a backgro...

Page 7: ...to 55 minutes G Room Controller Send Temperature value Send Humidity value Cyclic sending Note Per default the SHC Climate Function expects within every hour a temperature value Set the protection tim...

Page 8: ...nnected to the SHC are indicated by a light blue dashed line 7 SHC settings A Right click on the SHC Icon and select Settings B Select Tab Devices Zones C Import the Project Topology as SHC Zones and...

Page 9: ...in MRF 2 Function Light Heating Window Door Consumption 3 Extra 1 Contact type Unit 4 Extra 2 Custom ON System default if not set ON CLOSED MOTION 5 Extra 3 Custom OFF System default if not set OFF O...

Page 10: ...nd checked for updates If not follow Appendix A Activate and check for updates Find also detailed information in the SHC Help file SHC Setup steps 1 Login into the Web Admin Console See section 4 7 Wa...

Page 11: ...check option Advanced F To enable remote access check option Remote Remote access is only possible when Global Remote Access is enabled See Appendix A section A 1 step 5 Enable Global Remote Access 4...

Page 12: ...or the Night Orientation See help file 5 3 2 Macros C Create some planner events to switch the lights automatically See help file 5 1 Tab Planner D Enable and configure the Alarm Function if needed Se...

Page 13: ...nload and connect the App This example is based on the iPhone Figure 1 Download App Open the App Store Search for Eaton Install and open the App Figure 2 Connect to Smart Home Controller when in the s...

Page 14: ...ontrol Select the Climate Function Figure 3 Start the Temperature Control Click Edit Select Heating And Close Select a predefined mode The question mark indicates that no temperature value has been re...

Page 15: ...t the Status Control Function to set the preferred light settings Figure 4 Create a Light Scene 1 Select Status Control Set preferred Lights Select Scene Function And click Edit Click Figure 5 Create...

Page 16: ...le to restore the SHC configuration 2 Open the original used MRF Project for your SHC in the new MRF V2 42 or higher 3 Right click on the Smart Home Controller and select Scan Device new Only necessar...

Page 17: ...on local network have no internet access 3 Is the Global Remote Access enabled Enable Global Remote Access Menu Diagnostics System Status Enable the Remote for User admin Menu System Users 3a Initial...

Page 18: ...net connection via a PC or laptop RF Traffic LED o Blinking Green RF traffic System Message LED o Green There are no new messages in the Mailbox o Yellow New Warning Message in the Mailbox o Red New E...

Page 19: ...the System by removing the power plug for 1 minute and reconnect Reboot the Smart Home Controller via the Web Admin Console Set the Smart Home Controller back to factory settings Reconfigure everythi...

Page 20: ...th the login page 4 8 Default admin password The default password for admin is admin Please change this password directly after the setup 4 9 Diagnostics Status bar Indicators and colors In the top ba...

Page 21: ...ew Messages available in the System Log o Green No new messages after the last check o Yellow New Warning messages o Red New Error messages Battery status battery powered Devices o Green All batteries...

Page 22: ...nd Accept the Terms And Conditions Accept 4 Please wait until the popup disappears 5 Enable Global Remote Access 6 Refresh the page to check the connection status 7 Please make a note of the received...

Page 23: ...SW update a new version of the RF module firmware should become available Always install the new firmware in this case the Update button is available a Open Tab 1 Diagnostics System Status SHC 2 0 me...

Page 24: ...Email Address Used Smartphone Tablet and browsers iPhone App iOS Version iPad App iOS Version Andoid Phone App Android Version Andoid Pad App Android Version Safari Browser Version Google Chrome Brows...