6.0  Ordering Guidelines

Table 5.  Eaton SPD Max Series

SPM

kA Rating Options

100kA Per Phase
120kA Per Phase
160kA Per Phase
200kA Per Phase
250kA Per Phase
300kA Per Phase
320kA Per Phase
400kA Per Phase
600kA Per Phase

800kA Per Phase

Voltage Code Options

Feature Package Options

1

 = Basic. 

 

    Dual colored LED per Phase to indicate Protection status 

 

    Dual colored LED to indicate protection status of the N-G Mode on

                           units with a Neutral Wire

 
 

 
 

 

3

 = Standard With Surge Counter 

 

   

Dual colored LED Per Phase to indicate Protection Status 

 

                     Dual colored LED to indicate Protection Status of the N-G Mode on  

                           units with a Neutral Wire

                      Audible alarm with Silence button     

     

     

    

                      Form 'C' Relay Contact    

                     EMI/RFI filtering Providing up to 50dB of Noise Attenuation from   

    

10kHz to 100Mhz  

         

                      

Surge Counter with Alarm Silence (Reset) Button

240S

 = 120/240 Split Phase

208Y

 = 120/208 Wye (4W + G)

220Y

 = 127/220 Wye (4W + G)

400Y

 = 230/400 Wye (4W + G)

480Y

 = 277/480 Wye (4W + G)

600Y

 = 347/600 Wye (4W + G)

240D

 = 240 Delta (3W + G)

480D

 = 480 Delta (3W + G)

600D

 = 600 Delta (3W + G)

240H

 = 240 Delta High Leg (4W + G) on 'B' Phase

230L

  = 230 Single Phase* 

NOTE:

 Please consult the factory for 240 Delta High 

Leg  (4W+G) applications with high leg on 'C' Phase

Application Suffix

R

 = 1 Brick, NEMA 4 Enclosure with Internal Circuit Breaker 

 = 2 Brick, NEMA 4 Enclosure with Internal Circuit Breaker

T

 = 1 Brick, NEMA 4 Enclosure with Internal Terminal Block

U

= 2 Brick, NEMA 4 Enclosure with Internal Terminal Block

V

 = 1 Brick, NEMA 4X Enclosure with Internal Circuit Breaker

W

 = 2 Brick, NEMA 4X Enclosure with Internal Circuit Breaker

X

 = 1 Brick, NEMA 4X Enclosure with Internal Terminal Block

Y

 = 2 Brick, NEMA 4X Enclosure with Internal Terminal Block

SPM   250  480D  3   R

Example: SPD250480D3R = SPD Max Series, 250kA Per Phase, 480D Voltage, Standard with Counter Feature Package, NEMA 4 Enclosure 

with Internal Circuit Breaker.

Summary of Contents for SPD Series

Page 1: ...Installation 3 3 0 Operating Features 6 4 0 Troubleshooting 8 5 0 Specifications 9 6 0 Ordering Guidelines 10 7 0 Warranty 16 Effective October 2018 Supersedes October 2014 Instruction Booklet IB15800...

Page 2: ...d for UL96A and NFPA 780 Compliance 1 3 Safety Precautions A licensed qualified electrician must complete all instructions in this manual in accordance with the National Electric Code NEC Canadian Ele...

Page 3: ...T BREAKER PANEL FAILURE TO DO SO COULD RESULT IN INJURY OR DEATH FROM ELECTRICAL SHOCK NOTICE A POOR GROUND OR GROUNDING BONDING VIOLATIONS COULD PREVENT THE SPD FROM PERFORMING AS SPECIFIED DO NOT US...

Page 4: ...he SPD enclosure If using the Form C contacts route Form C wires through a separate maximum inch trade size hub and conduit 4 Determine the hole location on the receiving electrical enclosure and eith...

Page 5: ...two SPDs SPD1 and SPD2 the display cable and two SPD Status ribbon cables must be unplugged In either case this is done by loosening the two Cable Hold Down Bracket screws 1 2 turn and sliding the br...

Page 6: ...he Ground terminal block 180o and mount the two terminal blocks in the mounting holes located on the bottom left of the unit See Figure 5 Figure 5 Neutral and Ground Terminal Block re located for Top...

Page 7: ...off power to the unit 2 Remove the two phillips head screws that hold the display 3 Rotate the display to the desired position Be careful not to over stress the display ribbon cable 4 Place the displ...

Page 8: ...lay Neu Gnd Green LED is OFF Neu Gnd Red LED is ON Audible Alarm is ON for models with Neutral connections Neu Gnd protection is compromised or lost Replace SPD See Note Significant surge event Replac...

Page 9: ...ase Wye L N L G N G L L Three phase high leg delta L N L G N G L L Maximum continuous operating voltage MCOV 230V Single Phase 320V L N 320V L G 320V N G 127V 220V WYE 120V 240V Single Split Phase 150...

Page 10: ...10kHz to 100Mhz Surge Counter with Alarm Silence Reset Button 240S 120 240 Split Phase 208Y 120 208 Wye 4W G 220Y 127 220 Wye 4W G 400Y 230 400 Wye 4W G 480Y 277 480 Wye 4W G 600Y 347 600 Wye 4W G 240...

Page 11: ...02EN Effective October 2018 Eaton SPD Max Series Surge Protective Device EATON www eaton com Figure 8 DELTA 3W G with Circuit Breaker Figure 9 Wye 4W G with Circuit Breaker SPD2 only installed in mode...

Page 12: ...r 2018 Eaton SPD Max Series Surge Protective Device EATON www eaton com Figure 10 High Leg Delta 4W G with Circuit Breaker Figure 11 Split Phase 3W G with Circuit Breaker RED RED RED RED RED RED SPD2...

Page 13: ...02EN Effective October 2018 Eaton SPD Max Series Surge Protective Device EATON www eaton com Figure 12 DELTA 3W G with Terminal Block Figure 13 Wye 4W G with Terminal Block SPD2 only installed in mode...

Page 14: ...er 2018 Eaton SPD Max Series Surge Protective Device EATON www eaton com Figure 14 High Leg Delta 4W G with Terminal Block Figure 15 Split Phase 3W G with Terminal Block RED RED RED RED RED RED SPD2 o...

Page 15: ...15 Instruction Booklet IB158002EN Effective October 2018 Eaton SPD Max Series Surge Protective Device EATON www eaton com Figure 16 Product Dimensions...

Page 16: ...ng the SPD or for warranty information call 1 800 809 2772 Option 4 sub option 2 Repair or replacement units will be returned collect If Eaton finds the return to be a manufacturer s defect the produc...

Reviews: