USAGE INSTRUCTIONS FOR THE SURE-LITES EAGLE EYE 

SELF DIAGNOSTICS 

The Sure-Lites Eagle Eye Self Diagnostics is continuously 
monitoring your emergency fixture, and will signal any failure 
through the 3 color indicator LED.

 

Initial Operation

When the unit is first powered up, it will go into a 24 hour fast 
charge, indicated by the indicator LED pulsing green.  Once the 
unit has fully charged, it will perform a self-calibration, after 
which the LED will change to steady green, indicating the unit 
is fully charged and float charging the battery to maintain 
readiness.

Automatic Testing

The unit will perform a battery capacity, lamp/LED, and charge 
circuit test every 30 days for 30 seconds.  During this time, the 
indicator LED will change to a steady yellow.  It will perform a 
full battery capacity (90 minute) test once per year.  During this 
time, the indicator LED will change to a blinking yellow.

Manual Testing

•  10 Second “Installation” test – Press and release the test 

button once during fast charge (blinking green) to initiate 
a 10 second quick test. The sign and LED lamps will switch 
to emergency mode for 10 seconds allowing the installer to 
verify proper installation of the unit, and the LED indicator 
will turn solid yellow. 

•  30 Second Test - Press and release the test button once 

during float charge (steady green). The indicator LED will 
turn steady yellow to indicate the unit is performing a 30 
second test of the batteries and LED lamps.

•  90 Minute Test - Press and release the test button a second 

time during a 30 second test (steady yellow) to change to 
a 90 minute test. During this test, the LED indicator will 
change to blinking yellow, and the circuit will perform a full 
battery capacity, charge circuit, and LED test.

•  Canceling Test – Press and release the test button during the 

90 minute test (flashing yellow) to return the fixture to its 
original state (fast charge or float charge).

Clearing Failure Codes

•  A battery failure (LED two blink red) can be cleared by 

replacing the battery. Disconnecting the battery and AC 
power, or performing a full 90 minute discharge, will reset 
the error code, however, it will return if the battery is faulty.

•  Charge Circuit (LED three blink red) and lamp/LED failure 

(LED four blink red) will clear when the unit successfully 
passes a manual or automatic 30 second test.

Indicators

•  LED Off - No power to unit, emergency mode.
•  LED Steady Green - Unit is fully charged and is float 

charging the battery to maintain readiness.

•  LED Green Pulse - Unit is in a 24 hour fast charge of the 

battery.

•  LED Two Blink Red - Battery has failed a capacity test, or 

the battery is disconnected.  See “Clearing Failure Codes” 
above.

•  LED Three Blink Red - Battery charge circuit has failed.  See 

“Clearing Failure Codes” above.

•  LED Four Blink Red - Lamps have burned out, or 50% or 

more of the sign LEDs have failed. See “Clearing Failure 
Codes” above.

•  LED Steady Yellow - 30 second test or 10 second quick test 

(Fast Charge only).

•  LED Blinking Yellow - 90 minute test.

SURE-LITES

 

STEADY BLINK 

GREEN - FAST 

CHARGE

STEADY YELLOW - 

QUICK TEST

4 BLINK RED - LAMP / 

LED FAILURE

3 BLINK RED - CHARGE 

CIRCUIT FAILURE

STEADY BLINK YELLOW 

- 90 MINUTE TEST

STEADY GREEN - 

FULL / FLOAT 

CHARGE

2 BLINK RED - 

BATTERY FAILURE

OFF - EMERGENCY 

MODE / POWER OFF