18
www.eaton.com/wireless
call toll free: 1-800-663-8806
DM-R260-0056A R1
Service Mode: Pair WSO
Pair WSO
This function allows you to pair the TD3100 with a WSO accessory.
Pairing is required to teach a WSO unique configuration to a RCU. Once complete the WSO is capable of establish-
ing a radio link with a unique RCU.
Pairing is a three step process
1. Prepare the TD3100
2. Prepare the WSO accessory
3. Start
Pairing
The following sections describes the three-step process to pair the WSO to a TD3100.
1. Prepare the TD3100
On the TD3100 navigate to the screen on the right
.
Do not
press
[ENTER].
NOTE:
It is necessary to pair the WSO to a RCU when replacing either the RCU or WSO.
2. Prepare the WSO
1. Start with the anchor in its normal location and wait for
Link
light to go
off
.
Link:
off
2. Remove the anchor from the normal location
.
3. Hold the anchor over the pairing corner of the WSO
until the
Link
light turns solid green for 5 seconds. After 5 seconds the
link
light will
slow flash green
.
Link:
slow flash green
4. Reattach the anchor and the
link
will slow flash blue
.
Link:
slow flash blue
The WSO is now ready to pair with TD3100.
Light Legend
Solid
Slow
Flash
Fast
Flash
Red
Solid
Green
Solid
Red & Green
Alternating
Yellow
Solid
NOTE:
If the WSO is left in Pairing Mode idle for over 30 seconds, the WSO will time out. The
Link
light
will rapidly flash red two to three times after it times out. To return to Pairing Mode repeat step 2.
NOTE:
Your system may not support the use of WSO accessory.