22
www.eaton.com/wireless
call toll free: 1-800-663-8806
DM-R260-0056A R1
Service Mode: Run Diagnostics
Run Diagnostics
This function allows you to run TD3100 diagnostics.
Diagnostics allow you test the functionality of buttons and E-Stop.
To run diagnostics on the TD3100 navigate to the screen on the right
press [ENTER] and follow the procedures below.
See the diagram below for screen navigation.
Test Screen Buttons
1. On the TD3100 navigate to the screen on the right
and press
[ENTER]
2. The screen will prompt you to press any button
.
3. Press the button to test. If the button is functioning it will place a
0
in
the following respective position (left to right):
Position 1 = Top Left button
Position 2 = Bottom Left button
Position 3 = Top Right button
Position 4 = Bottom Right button
Position 5 = Power button
4. To quit button testing press [EXIT] and hold for 2 seconds.
If a button will not function make sure the button is clean of any debris and
repeat the test. After cleaning, if the button still does not function then con-
tact you service representative for assistance.
CAUTION:
Only clean a button or the TD3100 with a soft cloth lightly dampened with water.
DO NOT clean a button or the TD3100 with any sharp instruments or objects that can
cut or damage the button membrane or housing. DO NOT pour any liquids, use a hose,
or pressured water directly on the TD3100. Consult with the supplier of your equipment
if your are unsure of correct cleaning procedures.
Failure to follow CLEANING PROCEDURES may result in equipment failure and serious
personal injury.
Test
buttons
Test
controls
Test
E-Stop
Update
firmware
Export
log file