background image

8

Figure 3. Exploded View

 

Included in 920211 seal kit.

–S30 Equivalent seal kit 920235

FCGT–02–A–004–11–(S30)
FCGT–02–A–028–11–(S30)
FCGT–02–A–220–11–(S30)
FCGT–02–A–530–11–(S30)
FCGT–02–B–004–11–(S30)
FCGT–02–B–028–11–(S30)
FCGT–02–B–220–11–(S30)
FCGT–02–B–530–11–(S30)

Description

Source

code

A
B
C
D
E
F
G
H

NOTE

When Usable On Code is blank, the part is
used on all models tabulated in source code.
When Usable On Codes are listed, use with
indicated models only.

Index

No.

Description

Qty.

Usable

 On Code

1
2
3
4
5
6
7
8
9

10

11
12

13
14
15

154011

166772
179263
243233
235068

7889

234484
125792
176021
207961
207692

211458

212619
234483
234485
238129
234478
192435
238127

“O” Ring
“O” Ring
Screw
Elect. Connector
Gasket
Screw
Cover
Screw
Lockwasher
Torque Mtr. (280 Ohms)
Torque Mtr. (2200 Ohms)
Torque Mtr. (5300 Ohms)
Torque Mtr. (40 Ohms)
Spacer
Spool wire & screw S/A
Spool wire & screw S/A
Gasket
Washer
Sleeve

2
1
4
1
1
4
1
4
4
1
1
1
1
1
1
1
1
1
1

BF
CG
DH
AE

EFGH
ABCD

ABCD
ABCD

Part No.

Index

No.

Description

Qty.

Part No.

16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35

233625
234939
166772
234964
224342
312383
317922
153950

7076

95633
79795

239034

7074

160571
328055
416834
247278
242123
126058
595310

Retaining Ring
Retainer
“O” Ring
Spring
Hydrostat
Retaining Ring
Retainer
“O” Ring
Plug
Spring
Check Valve
Seat
Plug (Aux. Drain port)
Pin
Body
Rivet
Nameplate
Connector
Clamp
Adapter

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1

35

34

33

5

4

3

22

23

21

24

27

26

25

28

30

29

1

15

14

2

16

17

18

19

20

11

13

12

31

6

7

8

9

32

10

Usable

 On Code

Summary of Contents for Vickers FCGT-02-A-004-11

Page 1: ...I 3419 S Reprinted 6 1 96 Remote Flow Control Valves FCGT 02 A B 11 S30 Overhaul Manual Vickers Flow Controls...

Page 2: ...Installation Drawing 5 B Mounting 5 C Piping and Tubing 5 D Hydraulic Fluid Recommendations 5 E Overload Protection 5 V Service and Maintenance 6 A Inspection 6 B Adding Fluid to the System 6 C Adjust...

Page 3: ...ariations within each basic model series are covered in the model code Table 2 is a complete breakdown of the model codes covering these units Service inquiries should always include the complete unit...

Page 4: ...ow Control Valve as being two distinct and separate systems one a standard compensated flow control with a fixed throttle setting and secondly an electrically modulated device torque motor used to var...

Page 5: ...g wire brushing and pickling NOTE For instructions on pickling refer to instruction sheet 1221 S 2 To minimize flow resistance and the possibility of leakage only as many fittings and connections as a...

Page 6: ...ed Sophisticated design processes and materials are used in the manufacture of our parts Substitutions may result in early failure Part numbers are shown in the parts listing reference Figure 3 F Prod...

Page 7: ...es 4 Symbolize each wire with a piece of tape to allow reassembly to the same pin of the connector Unsolder the four wires from connector 4 Remove connector and gasket 5 NOTE Hold the valve over a con...

Page 8: ...Ring O Ring Screw Elect Connector Gasket Screw Cover Screw Lockwasher Torque Mtr 280 Ohms Torque Mtr 2200 Ohms Torque Mtr 5300 Ohms Torque Mtr 40 Ohms Spacer Spool wire screw S A Spool wire screw S A...

Page 9: ...luded in the following steps See Figure 3 1 If nameplate 32 was removed install a new name plate with four screws 31 2 Install parts 29 through 24 into body 30 If seat 27 or check valve 26 were defect...

Page 10: ...resistance ohms wire code Series aiding Parallel Differential 40 Yellow 150 ma 300 ma N A 280 White 50 ma 100 ma 100 ma 2200 Blue 20 ma 40 ma 40 ma 5300 Black 12 5 ma 25 ma 25 ma Table 5 Input curren...

Page 11: ...il 3000 PSI is read on gage 5 and globe valve 1 is completely closed d Open globe valve 6 NOTE Valve may be unstable until all air is purged from the system Allow at least one minute for valve to stab...

Page 12: ...delivering 0 300 mA DC to a 20 OHM inductive load 10 Pressure gage 0 3000 psi 11 Load relief valve 12 Globe valve 13 Flow meter 14 Electric drive motor approximately 10 hp for 5 gpm 3000 psi 15 1 2 G...

Reviews: