Interfaces
15
DIX2
dimmer interface
Built-in module
Product description
The DIX2 is a dimmer interface that can be mounted
in a junction box located behind a toggle pulse switch.
By applying the DIX2, lighting provided with a
dimming actuator can also be switched or dimmed
by remote control.
Characteristics
•
Sends ON/OFF and DIM commands
•
Can control up to a maximum of two addresses
•
Two wires per address; 1 for on/bright and 1
for off/dim
•
Can only be applied with toggle pulse switches
•
Status can be requested after commands
have been sent
Operation
The wires of the DIX2 module can be connected to
potential-free (toggle) pulse switches. With one module,
a maximum of two addresses can be controlled by
connecting it to, for example, one 2-way toggle pulse
switche or two 1-way toggle pulse switches.
Installation instructions
•
Phase and neutral wiring must be fitted.
•
The junction box must be at least 40 mm deep
Adres
DIX2
N N
Prog.
Pulse switch
(Max. 2)
Adres
DIX2
N N
Prog.
DIX2
Adres
VIX10
N N
Prog.
Adres
VIX10
N N
Prog.
VIX10
ventilator interface
Built-in module
Product description
The VIX10 is a ventilator interface that can be mounted
in a junction box located behind 4-way pulse switches. It
can control, via the lighting network, 2 SAX1 modules
that operate air-suction-ventilators installed in homes.
These ventilators have three operating positions. By
applying several VIX10 interfaces, it is possible to
operate the three positions of the mechanical ventilator
from various places in the home.
Characteristics
•
Sends ON/OFF commands over two addresses
•
Can be applied in combination with a 3 or
4-way pulse switch
•
Including a sticker with position indicator for
attaching to the pulse switch
Operation
The wires of the VIX10 module can be connected to a
potential-free 3 or 4-way pulse switches. With this pulse
switch, it is possible to send VIX10 Xanura commands
to the switch actuators that feed the mechanical
ventilator provided with three operating positions.
Installation instructions
•
Phase and neutral wires must be fitted
•
Junction box must be at least 40 mm deep
•
Two actuators (SAX1) must be fitted for switching
the ventilator box
Adres
VIX10
N N
Prog.
Adres
VIX10
N N
Prog.
Adres
VIX10
N N
Prog.
Adres
SAIX
Prog.
N
N
L
Adres
SAIX
Prog.
N
N
L
By fitting more VIX10 ventilator interfaces in the building
(phase and neutral) the ventilator box actuators can be
switched. In this way, it is possible to operate the three
operating positions from different places in the home.
In combination with the computer interface (CIX), time
functions are also possible. (e.g. bathroom lights off,
ventilator operates for 15 minutes in the high
position and thereafter in the low position).