Interfaces

15

DIX2 

dimmer interface

Built-in module 

Product description

The DIX2 is a dimmer interface that can be mounted 

in a junction box located behind a toggle pulse switch.

By applying the DIX2, lighting provided with a 

dimming actuator can also be switched or dimmed 

by remote control. 

Characteristics

Sends ON/OFF and DIM commands

Can control up to a maximum of two addresses

Two wires per address; 1 for on/bright and 1 

for off/dim

Can only be applied with toggle pulse switches 

Status can be requested after commands 

have been sent

Operation

The wires of the DIX2 module can be connected to

potential-free (toggle) pulse switches. With one module,

a maximum of two addresses can be controlled by

connecting it to, for example, one 2-way toggle pulse

switche or two 1-way toggle pulse switches. 

Installation instructions

Phase and neutral wiring must be fitted.

The junction box must be at least 40 mm deep

Adres

DIX2

N N

Prog.

Pulse switch
(Max. 2)

Adres

DIX2

N N

Prog.

DIX2

Adres

VIX10

N N

Prog.

Adres

VIX10

N N

Prog.

VIX10 

ventilator interface

Built-in module

Product description

The VIX10 is a ventilator interface that can be mounted

in a junction box located behind 4-way pulse switches. It

can control, via the lighting network, 2 SAX1 modules

that operate air-suction-ventilators installed in homes.

These ventilators have three operating positions. By

applying several VIX10 interfaces, it is possible to

operate the three positions of the mechanical ventilator

from various places in the home.

Characteristics

Sends ON/OFF commands over two addresses

Can be applied in combination with a 3 or 

4-way pulse switch

Including a sticker with position indicator for 

attaching to the pulse switch 

Operation

The wires of the VIX10 module can be connected to a

potential-free 3 or 4-way pulse switches. With this pulse

switch, it is possible to send VIX10 Xanura commands

to the switch actuators that feed the mechanical

ventilator provided with three operating positions.

Installation instructions

Phase and neutral wires must be fitted

Junction box must be at least 40 mm deep

Two actuators (SAX1) must be fitted for switching 

the ventilator box

Adres

VIX10

N N

Prog.

Adres

VIX10

N N

Prog.

Adres

VIX10

N N

Prog.

Adres

SAIX

Prog.

N

N

L

Adres

SAIX

Prog.

N

N

L

By fitting more VIX10 ventilator interfaces in the building

(phase and neutral) the ventilator box actuators can be

switched. In this way, it is possible to operate the three

operating positions from different places in the home. 

In combination with the computer interface (CIX), time

functions are also possible. (e.g. bathroom lights off,

ventilator operates for 15 minutes in the high

position and thereafter in the low position).

Summary of Contents for Xanura

Page 1: ...me automation Xanura home automation system Home automation for new and existing buildings Technical description Application examples Installation tips Functionalities Sales support Ordering informati...

Page 2: ...e modular concept 4 Functionalities Xanura 6 Operation 8 Product description 11 Switching actuators 11 Dimming actuators 12 Interfaces 13 RF components 19 Remaining components 20 Practical examples 22...

Page 3: ...ing work is not necessary and installation and material costs are therefore greatly reduced By fitting transmitting and receiving components behind switches and wall sockets so that they are invisible...

Page 4: ...witching Operation of the TV or audio with one universal remote control device ABX1 Lamps 3 and 4 can be dimmed or switched independently with the DIX2 and universal remote control device ABX1 Outside...

Page 5: ...vators GIX Group Interface Xanura Mounted behind switches or pulse switches For control of various activators by means of group commands AIX12 On Off Interface Xanura Mounted behind for example any 23...

Page 6: ...es or scenarios can be switched on or off with a mobile telephone by simply phoning into the Xanura system Which automatic switching operations are possible with Xanura Each light appliance provided w...

Page 7: ...intervals When something wrong occurs all the downstairs lights can be switched on from one switch in the bedroom When outdoor movement is detected the outdoor lighting is turned on and for instance 1...

Page 8: ...and switches without being visible Switching actuators Two types of switching actuator modules are available for application with Xanura i e one for mounting behind wall junction boxes and another fo...

Page 9: ...fferent lamps can be switched at various times Almost all switching operations that can be translated into conditions and actions IF THEN can be easily programmed in the computer interface with the Wi...

Page 10: ...taken into consideration This means that a neutral wire has to be run through to the junction boxes where switches are fitted In brief a newly built home provided with 50 mm junction boxes and phase...

Page 11: ...thed wall sockets a junction box of 50 mm is required Junction box Adres SAX1 Prog N N L Prog Adres SAX1 N N L SAX1 2 address is free for use switch pulse switch Adres SAIX Prog N N L nd P Adres SAIX...

Page 12: ...ching can be carried out in combination with dimmer interfaces Installation instructions Phase and neutral wiring must be fitted Junction box must be at least 40 mm deep Adres DAIX10 Prog Toggle pulse...

Page 13: ...must be at least 40 mm deep Interfaces To operate the switching dimming actuators that have been fitted interfaces are required When desired each switching actuator can be controlled by more than one...

Page 14: ...itches pulse switches can be connected to a GIX A maximum of 16 addresses can be controlled with one GIX by means of group commands Operation The wires of the GIX module can be connected to a potentia...

Page 15: ...X1 modules that operate air suction ventilators installed in homes These ventilators have three operating positions By applying several VIX10 interfaces it is possible to operate the three positions o...

Page 16: ...e CIX it is possible to store individual Xanura scenarios that can be carried out in a home provided with Xanura components The CIX electronic clock calendar makes it possible to carry out the scenari...

Page 17: ...tus request is possible Request for the status after commands have been sent is possible Length of the primary supply cable is 1 5 m is provided with an euro plug Operation The input connectors and sw...

Page 18: ...d Automatic status notification possible Request for the status after commands have been sent is possible Provided with 20 cm long wires Operation The input and output connectors work independently of...

Page 19: ...in the device Self programming for appliances that are not programmed Provides a number of standard group commands Range 30 metres in open space CAX RF Communication access interface Product descripti...

Page 20: ...se signals are then amplified to the maximum signal level and transmitted on all phases Installation instructions The phase coupler must be connected to a 16 A 3 phase circuit SFX40 suppression filter...

Page 21: ...amming unit Product description The PUX is an indispensible tool for the proficient installation of Xanura With this programming unit the Xanura modules can be easily programmed Furthermore Xanura com...

Page 22: ...e lights and TV video and audio appliances with only one remote control device When nobody is at home switching of the lights to give the impression that the home is occupied Varying daily sequences T...

Page 23: ...sily be changed software for other applications Due to the fact that the modules are fed by phase and neutral wires it is only necessary to fit a SAIX switch in the garden shed M Light m can thus be s...

Page 24: ...e protected electrical contractors section of www xanura nl In addition potential customers who ask Eaton Holec for more information can be referred to these contractors In this manner Eaton Holec inv...

Page 25: ...the CD ROM Live in your own home longer in which all the applications of Xanura that are related to the health care sector are explained CD ROM Easy living with Xanura To keep your customers informed...

Page 26: ...dule DIX2 1807 533 31726 0 Dim actuator built in module DAX10 1807 544 31553 2 Dim actuator dimmer interface built in module DAIX10 1807 543 32064 2 Group interface built in module GIX 1807 534 42126...

Page 27: ...Switching actuator 16 A modular SAX4 1807 520 53336 3 Sun blinds actuator ZAX 1807 537 53035 5 Movement detector RF BSX1 1807 506 42546 0 Suppression filter DIN modular component SFX40 1807 530 85312...

Page 28: ...vators GIX Group Interface Xanura Mounted behind switches or pulse switches For control of various activators by means of group commands AIX12 On Off Interface Xanura Mounted behind for example any 23...

Page 29: ...e SFX40 Basic package lighting and control 2 Type BPLX2 Eaton Holec No 1807 596 Reference No 531376 Contents Same as basic package lighting and control 1 with in addition 1 x Computer interface type C...

Reviews: