16
Interfaces
SAX15
potential-free actuator/interface
Built-in module
Product description
The SAX15 is a potential-free/interface in a module
housing for linking up, for example, the door bell or
electronic lock to Xanura. Heating systems (24 V a.c.) can
also be linked up.
Characteristics
•
2 inputs and 1 output
(potential-free and separated galvanically)
•
Sends ON/OFF commands (Max. 2 addresses)
•
Receives ON/OFF commands and transfers these
after the contacts of the built-in relay have closed
and opened respectively.(Max.5A 30 V)
•
Can be included in a group command
•
Automatic indication of status possible
•
Request for status after commands have
been sent is possible
•
Provided with 20 cm long wires
Operation
The input connectors and switch output
connector work independently of each
other. Send and receive addresses must
be programmed separately. The module
has two coupled send addresses and
one receive address. (Relay).
Installation instructions
•
Phase and neutral wiring must be fitted
•
External rated supply (+5 V...+24 V a.c.
or V d.c. for instance bell voltage)
required for feeding the input
connectors is max. 7.5 mA
Interfaces
communication with external equipment
Green
Red
Brown
S2
S1
Address 2
Address 1
SAX15
+
+
5...24Vac/dc
+
-
N
L
230V
50Hz
Address 3
Max. 5A
30Vac/dc
+
CIX
computer interface
Product description
In the CIX, it is possible to store individual Xanura
scenarios that can be carried out in a home provided with
Xanura components. The CIX electronic clock/calendar
makes it possible to carry out the scenarios on the
stipulated times and dates. Scenarios can
easily be added or changed by making use of the
associated Xanura software. With this software, it is also
possible to program so-called conditional scenarios such
as: "IF" the switch in the hall is switched on "AND" it is
dark, "THEN" the table lamps in the living room go on.
Characteristics
•
The plug is for feeding and communicating with
Xanura components
•
Works completely autonomously:
is disconnected from the PC
•
Simple connection with PC via com-gate for
program changes
•
Status of the lighting can be read if the PC is
online with the computer interface.
•
256 addresses that can immediately be switched
or dimmed to any dimming position desired
•
Clock/calendar function
•
Takes summer and winter time into account
•
Geographical clock keeps a record of dawn and
dusk times for the set geographical position
•
Extensive conditional switching scenarios
can be made
•
Programmed settings easy to print and store
in a neatly arranged manner
•
Switching groups easy to compose and alter
•
Easy to program
Operation
The CIX can be automatically operated by its own
electronic clock/calendar. Programming of the CIX
can be carried out by means of a PC and the
associated Xanura software. The CIX can be
operated online when a PC is connected to it.
CIX
easy to make scenarios