4 XN-312-GW-EC gateway object dictionary
4.3 Device parameter area
XN-312-GW-EC gateway 07/20 MN050010-EN
Eaton.com
41
4.3.7 System bus statistics (0×F120)
Object 0xF120 contains statistical data regarding the system bus.
4.3.8 Device control (0×FB00)
Object 0xFB00 contains gateway monitoring options.
22
The switch from ISO Full to the Read-Only task state on the system
bus failed
23
Excessively long filename
24
Bad checksum
Reason code
Error information
Index (hex)
Object
Name
M/O
0xF120
RECORD
SDIAS statistics
O
Sub-index
(hex)
Descrip-
tion
Default (hex)
Catalog
number
Access
#00
number of
entries
–
USINT
ro
#01
ISO write
task dura-
tion
0x00000000
UDINT
ro
#02
maximum
ISO write
task dura-
tion
0x00000000
UDINT
ro
#03
ISO read
task dura-
tion
0x00000000
UDINT
rw
#04
maximum
ISO read
task dura-
tion
0x00000000
UDINT
rw
Index (hex)
Object
Name
M/O
0xFB00
RECORD
Device control
O
Sub-index
(hex)
Descrip-
tion
Default (hex)
Catalog
number
Access
#00
number of
entries
–
USINT
ro
#01
software
restart
0x00
USINT
rw