9. Maintenance
9.1 Cleaning and maintenance
The battery in the Box-PC is located inside. You will need to open the device in order
to replace the battery.
ESD protection is required when working on the open device. Make sure to take all
necessary ESD protection measures.
CAUTION
Installation requires qualified electrician
CAUTION
Arrange for a qualified electrician or for EATON Service to replace
the battery.
In order to prevent damage to the device, do the following before opening the enclos-
ure:
Shut down the operating system.
Disconnect the power supply.
Open Box-PC
Remove the six screws (Torx A2 M3x8 ISO 14581) from the side of the enclosure
without cooling fins and store them safely.
T 2
2
1
Remove the enclosure cover.
The battery holder for replacing the battery will be accessible inside the com-
puter enclosure.