1. Description
1.9 Use in hazardous locations - ATEX
1.9 Use in hazardous locations - ATEX
The II 3D Ex tc IIIC T70°C U ATEX certification applies to devices with a Widescreen
terminal:
Panel-PCs, Terminals, and Terminal with Extender RX.
EXPLOSION HAZARD
Death, serious injury, and property damage may occur if the device
is being used in a potentially explosive (classified) location and,
during operation, an electrical plug-in connection is disconnected or
the device is exposed to dangerous impacts or other types of dan-
gerous mechanical shock.
Use the device in the following environments only:
l
Non-hazardous (non-explosive) areas
l
Potentially explosive atmosphere, Zone 22 (according to ATEX
Directive), only these devices:
l
XP-504-..-A10-A01-2. (Panel-PC)
l
XP-504-..-TERMINAL and
l
XP-504-..-TERMINAL-EXT
The ground resistance of accessible metal parts must be less
than 10
9
ohms
Make sure that the device is not exposed to dangerous impacts
and other types of dangerous mechanical shock.
De-energize the device before disconnecting plug connections.
Clean only with a clean soft antistatic damp cloth.
When used in a potentially explosive atmosphere, Zone 22:
The XP-504…-A10-A01-…, XP-504-..-TERMINAL and XP-504-..-
TERMINAL-EXT are designed for installation in the front of
enclosures in protection type "tc" (alternatively "ta" or "tb"). This
installation must be tested and certified separately. The maxi-
mum surface temperature at the outer surface is set to 70°C at
the maximum ambient temperature of 45°C. The environment
has to be designed to avoid any bunch discharge. For safe instal-
lation, comply with the specification to holding brackets and
tightening torque in the respective Instruction leaflet for the
device.
XP-504
04/2022 MN048028EN Eaton.com
27
Summary of Contents for XP-504-10-A10-A01-2B
Page 1: ...Manual 04 2022 MN048028EN XP 504 Manual...
Page 4: ......
Page 86: ...5 Commissioning 5 2 Running the XP 504 86 XP 504 04 2022 MN048028EN Eaton com...
Page 98: ...7 Operating System 7 2 Windows 10 Enterprise LTSC 98 XP 504 04 2022 MN048028EN Eaton com...
Page 100: ...8 Faults 100 XP 504 04 2022 MN048028EN Eaton com...
Page 130: ...Appendix A 2 Further usage information 130 XP 504 04 2022 MN048028EN Eaton com...