4. Using peripheral devices - External connections
4.5 Display interfaces
4.5 Display interfaces
There are two ports available for connecting additional HMI devices (terminals, mon-
itors, touchscreens) to the Human-machine interface.
4.5.1 DisplayPort (DP)
Available on: Panel-PC, Box-PC, Terminal, and Extender TX with varying pinouts
19 17 15 13 11
9
7
5
3
1
18 16 14 12 10
8
6
4
2
20
DP
Fig. 36: Pin assignment DP
Available on: Panel-PC and Box-PC
PIN
PIN
PIN
1
LANE 0_P
8
GND
15
AUX_DP
2
GND
9
LANE 2_N
16
GND
3
LANE 0_N
10
LANE 3_P
17
AUX_DN
4
LANE 1_P
11
GND
18
Hot Plug Detect
5
GND
12
LANE 3_N
19
GND
6
LANE 1_N
13
GND
20
+3.3V
7
LANE 2_P
14
GND
Available on: Terminal
PIN
PIN
PIN
1
LANE 3-
8
GND
15
AUX CH+
2
GND
9
LANE 1+
16
GND
3
LANE 3+
10
LANE 0-
17
AUX CH-
4
LANE 2-
11
GND
18
Hot Plug Detect
5
GND
12
LANE 0+
19
Return
6
LANE 2+
13
GND
20
DP Power
7
LANE 1-
14
GND
Available on: Extender TX
PIN
PIN
PIN
1
n.c.
8
GND
15
AUX CH+
2
GND
9
LANE 1+
16
GND
3
n.c.
10
LANE 0-
17
AUX CH-
4
n.c.
11
GND
18
Hot Plug Detect
5
GND
12
LANE 0+
19
Return
6
n.c.
13
GND
20
n.c.
7
LANE 1-
14
GND
78
XP-504
04/2022 MN048028EN Eaton.com
Summary of Contents for XP-504-10-A10-A01-2B
Page 1: ...Manual 04 2022 MN048028EN XP 504 Manual...
Page 4: ......
Page 86: ...5 Commissioning 5 2 Running the XP 504 86 XP 504 04 2022 MN048028EN Eaton com...
Page 98: ...7 Operating System 7 2 Windows 10 Enterprise LTSC 98 XP 504 04 2022 MN048028EN Eaton com...
Page 100: ...8 Faults 100 XP 504 04 2022 MN048028EN Eaton com...
Page 130: ...Appendix A 2 Further usage information 130 XP 504 04 2022 MN048028EN Eaton com...