Device overview / main components
3
2.3 Maintenance and repair work
The plug must be pulled from the power supply for all installation and maintenance work.
Maintenance and repair work may only be performed by service technicians authorised by EauVation.
Inappropriate maintenance or repair work can result in serious risks for the user, for which EauVation
shall not accept liability.
Original spare parts must be used for repairs or to replace consumable parts. If original spare parts are
not used, the warranty is invalidated.
Caution
Possible leakage from improperly cut hoses
Use the hose cutter to ensure the hose cross section remains round and that the hose is
cut straight.
Caution
Possible leakage from damaged hoses
Check the hose. If there are any scores on the hose, shorten the hose or replace it to
ensure a tight plug connection.
3
Device overview / main components
Front view
Rear view
Item Description
1
Operating panel
2
Water outlet
3
Drip tray with mesh
Item Description
4
Ice-bank water supply
5
Thermostat (adjustable)
6
Main switch
7
Electrical supply
8
Hose connection for the drip tray
9
Connection for carbonic acid
10
Water connection
11
Ice-bank level indicator
12
Programming button (setting the portioning)
13
Mains cable with plug
14
Water hose / Waste water hose for drip tray
15
Carbonic acid hose
Summary of Contents for Acqua 80