background image

12

 – CAZ Series

8. SPECIFICATIONS

Continuous Sine Wave Average Output Power, 

 

both channels driven, 20 Hz to 20 kHz

 

CAZ800 CAZ1400 

CAZ2500

2 ohms: 

480 W 

 800 W 

1400 W

4 ohms: 

300 W 

 450 W 

750 W

8 ohms: 

205 W 

 310 W 

575 W

Bridged Mono Operation, 20 Hz to 20 kHz

 

CAZ800 CAZ1400 

CAZ2500

4 ohms: 

800 W 

1400 W 

2500 W

8 ohms: 

560 W 

  900 W 

1500 W

Note:

 Power ratings are specifi ed at 120 VAC line voltage.

Power Bandwidth

5 Hz to 50 kHz (+0, –3 dB)

Frequency Response

25 Hz to 25 kHz (+0, –1 dB)

Distortion

THD and SMPTE IMD; 20 Hz to 20 kHz
            < 0.03 % @ 8 ohms

Signal-to-Noise Ratio

> 100 dB below rated power into 4 ohms

Channel Separation

> 90 dB @ 1 kHz

Damping Factor

> 300 @ 1 kHz and below

Input Impedance

20 k

 balanced

10 k

 unbalanced

Input Sensitivity

1.15 V (+3.4 dBu) for rated power into 4 ohms

Gain

CAZ800:                      30 dB
CAZ1400:                    32 dB
CAZ2500:                    34 dB

Maximum Input Level

9.75 Vrms (+22 dBu)

Turn On Delay

2.5 seconds

Subsonic Filter

– 9 dB @ 30 Hz

Topology

CAZ800, CAZ1400:                      Class AB
CAZ2500:                                      Class H

Cooling

Dual variable-speed fans with back to front airfl ow

Indicators

Channels A and B
            SIG (Signal Present), OL (Overload)
POWER

Current Consumption

 

 

 

 

CAZ800 CAZ1400 

CAZ2500

Idle 

0.5 A 

0.5 A 

1.0 A

Musical Program @ 8

 

3.9 A 

5.1 A 

8.1 A

Musical Program @ 4

 

5.0 A 

6.7 A 

10.0 A

Musical Program @ 2

 

7.0 A 

10.6 A 

17.2 A

AC Power Requirements

            U.S.                                   120 VAC, 60 Hz
            Europe                              240 VAC, 50 Hz

Physical Dimensions and Weight

Height:                                         3.5 in/89 mm
Width:                                          19.0 in/483 mm
Depth:                                          15.7 in/400 mm
Weight:
            CAZ800:                            43.6 lb/19.8 kg
            CAZ1400:                          48.5 lb/22.0 kg
            CAZ2500:                          56.2 lb/25.5 kg

Warranty

5 years, parts and labor

DISCLAIMER

EAW Commercial continually engages in research related 

to product improvement, new materials, and production 
methods. Design refi nements are introduced into existing 
products without notice as a routine expression of that 
philosophy. For this reason, any current EAW Commercial 
product may differ in some respect from its published 
description, but will always equal or exceed the original design 
specifi cations unless otherwise stated.

“EAW Commercial” is a trademark of LOUD Technologies 

Inc. All other brand names mentioned are trademarks or 
registered trademarks of their respective holders, and are 
hereby acknowledged.

Summary of Contents for CAZ1400

Page 1: ...ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE SEE INSTRUCTIONS BEFORE USING INPUT B LINE BALANCED B B B CHANNEL B BRIDGED CHANNEL A A A B GND A A INPUT A LINE BALANCED SERIAL DATE CO...

Page 2: ...tibility to noise induced hearing loss but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a period of time The U S Government s Occupational Safety and Health Admi...

Page 3: ...against permanent damage caused by overloading shorts and extreme temperatures The front panel incorporates holes for rack mounting and it will take up two rack spaces There are two handles fitted on...

Page 4: ...rols are turned all the way down fully counterclockwise these indicators will not light 5 LEVEL CONTROLS These two knobs control the levels of Channels A and B The knobs are detented to make it easy t...

Page 5: ...tually transparent meaning you probably won t even notice any audible difference when the switch is turned on We recommend that you leave this switch on at all times However if you are working at quie...

Page 6: ...s ways There are three pairs of terminals Use the two outer pairs CHANNEL A and CHANNEL B when using stereo or mono modes Use the center pair BRIDGED when using bridge mode Note When using bridge mode...

Page 7: ...cularly the power amplifiers This can easily damage the loudspeakers If driven into clipping even an amplifier with a power output rating lower than the loudspeaker s power rating can cause damage to...

Page 8: ...should overheat a thermal switch turns off the power amplifier allowing the heatsink to cool down Once the amplifier has cooled to a safe operating temperature the thermal switch resets and reactivat...

Page 9: ...less than 0 5 dB power losses are rarely practical for physical and cost reasons As a practical compromise for these situations the recommended conductor gauge is 10 AWG or 25 metric 6 CONNECTIONS Use...

Page 10: ...W IS A REGISTERED TRADEMARK OF LOUD TECHNOLOGIES INC CAUTION TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE SEE INSTRUCTIONS BEFORE USING SERIAL DATE COD...

Page 11: ...ION CAZ2500 AMPLIFIER MANUFACTURED IN CHINA 2004 LOUD TECHNOLOGIES INC EAW IS A REGISTERED TRADEMARK OF LOUD TECHNOLOGIES INC CAUTION TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS AP...

Page 12: ...fans with back to front airflow Indicators Channels A and B SIG Signal Present OL Overload POWER Current Consumption CAZ800 CAZ1400 CAZ2500 Idle 0 5 A 0 5 A 1 0 A Musical Program 8 3 9 A 5 1 A 8 1 A M...

Page 13: ...NEL B LEVEL SUBSONIC FILTER ON OFF ON OFF ON OFF ON PROTECTION DC OFFSET OVER TEMP SHORT CIRCUIT CURRENT LIMIT OFF CLIP LIMITER OL POWER AMPLIFIER VDC VDC CHANNEL A SPEAKER OUT BRIDGED SPEAKER OUT POW...

Page 14: ...sing Incorrect EQ settings in the electronic equipment Ensure all EQ settings and filters on the mixing console or preamplifier and on other equipment are set for normal operation Ensure level control...

Page 15: ...ical Support Phone USA Canada 888 337 7404 Phone 425 892 6503 Fax 425 485 1152 Address One Main Street Whitinsville MA 01588 Web site www eawcommercial com e mail support eawcommercial com 12 EAW COMM...

Page 16: ...ies Inc Company EAW Commercial One Main Street Whitinsville MA 01588 USA TEL toll free within US Canada 888 337 7404 TEL outside US 425 892 6503 FAX 425 485 1152 www eawcommercial com 2004 LOUD Techno...

Reviews: