background image

DX-RVC PREDEFINED FUNCTIONS

DX-RVC Remote Volume Control (For DX810 Applications)

        Switch Positions *
ID  1 through 8

Function

0

00000000

Input Level 1A

1

10000000

Input Level 1B

2

01000000

Input Level 1C

3

11000000

Input Level 1D

4

00100000

Input Level 1E

5

10100000

Input Level 1F

6

01100000

Input Level 1G

7

11100000

Input Level 1H

8

00010000

Input Level 1I

9

10010000

Input Level 1J

10

01010000

Input Level 2A

11

11010000

Input Level 2B

12

00110000

Input Level 2C

13

10110000

Input Level 2D

14

01110000

Input Level 2E

15

11110000

Input Level 2F

16

00001000

Input Level 2G

17

10001000

Input Level 2H

18

01001000

Input Level 2I

19

11001000

Input Level 2J

20

00101000

Input Level 3A

21

10101000

Input Level 3B

22

01101000

Input Level 3C

23

11101000

Input Level 3D

24

00011000

Input Level 3E

25

10011000

Input Level 3F

26

01011000

Input Level 3G

27

11011000

Input Level 3H

28

00111000

Input Level 3I

29

10111000

Input Level 3J

30

01111000

Input Level 4A

31

11111000

Input Level 4B

32

00000100

Input Level 4C

33

10000100

Input Level 4D

34

01000100

Input Level 4E

35

11000100

Input Level 4F

36

00100100

Input Level 4G

37

10100100

Input Level 4H

38

01100100

Input Level 4I

39

11100100

Input Level 4J

40

00010100

Input Level 5A

41

1001010

Input Level 5B

42

01010100

Input Level 5C

43

11010100

Input Level 5D

44

00110100

Input Level 5E

45

10110100

Input Level 5F

46

01110100

Input Level 5G

47

11110100

Input Level 5H

48

00001100

Input Level 5I

49

10001100

Input Level 5J

50

01001100

Input Level 6A

51

11001100

Input Level 6B

52

00101100

Input Level 6C

53

10101100

Input Level 6D

54

01101100

Input Level 6E

55

11101100

Input Level 6F

56

00011100

Input Level 6G

57

10011100

Input Level 6H

58

01011100

Input Level 6I

59

11011100

Input Level 6J

60

00111100

Input Level 7A

61

10111100

Input Level 7B

62

01111100

Input Level 7C

63

11111100

Input Level 7D

64

00000010

Input Level 7E

65

10000010

Input Level 7F

66

01000010

Input Level 7G

67

11000010

Input Level 7H

68

00100010

Input Level 7I

69

10100010

Input Level 7J

70

01100010

Input Level 8A

71

11100010

Input Level 8B

72

00010010

Input Level 8C

73

10010010

Input Level 8D

74

01010010

Input Level 8E

75

11010010

Input Level 8F

76

00110010

Input Level 8G

77

10110010

Input Level 8H

78

01110010

Input Level 8I

79

11110010

Input Level 8J

80

00001010

Output Level A

81

10001010

Output Level B

82

01001010

Output Level C

83

11001010

Output Level D

84

00101010

Output Level E

85

10101010

Output Level F

86

01101010

Output Level G

87

11101010

Output Level H

88

00011010

Output Level I

89

10011010

Output Level J

90

01011010

Group Level 1

91

11011010

Group Level 2

92

00111010

Group Level 3

93

10111010

Group Level 4

94

01111010

Group Level 5

95

11111010

Group Level 6

96

00000110

Group Level 7

97

10000110

Group Level 8

98

01000110

Group Level 9

99

11000110

Group Level 10

100 00100110

Group Level 11

101 10100110

Group Level 12

102 01100110

Group Level 13

103 11100110

Group Level 14

104 00010110

Group Level 15

105 10010110

Group Level 16

106 01010110

Group Level 17

107 11010110

Group Level 18

108 00110110

Group Level 19

109 10110110

Group Level 20

110 01110110

Group Level 21

111 11110110

Group Level 22

112 00001110

Group Level 23

113 10001110

Group Level 24

114 01001110

Group Level 25

115 11001110

Group Level 26

116 00101110

Group Level 27

117 10101110

Group Level 28

118 01101110

Group Level 29

119 11101110

Group Level 30

120 00011110

Group Level 31

121 10011110

Group Level 32

122-255

Reserved for future 
updates

       Switch Positions
ID  1 through 8

Function

DX-RVC Remote Volume Control (For DX8 Applications)

        Switch Positions *
  ID  1 through 8

Function

0

00000000

Input Level 1A (1)

1

10000000

Input Level 1A (2)

2

01000000

Input Level 1B (1)

3

11000000

Input Level 1B (2)

4

00100000

Input Level 2A (1)

5

10100000

Input Level 2A (2)

6

01100000

Input Level 2B (1)

7

11100000

Input Level 2B (2)

8

00010000

Input Level 3A (1)

9

10010000

Input Level 3A (2)

10

01010000

Input Level 3B (1)

11

11010000

Input Level 3B (2)

12

00110000

Input Level 4A (1)

13

10110000

Input Level 4A (2)

14

01110000

Input Level 4B (1)

15

11110000

Input Level 4B (2)

16

00001000

Input Level 5A (1)

17

10001000

Input Level 5A (2)

18

01001000

Input Level 5B (1)

19

11001000

Input Level 5B (2)

20

00101000

Input Level 6A (1)

21

10101000

Input Level 6A (2)

22

01101000

Input Level 6B (1)

23

11101000

Input Level 6B (2)

24

00011000

Input Level 7A (1)

25

10011000

Input Level 7A (2)

26

01011000

Input Level 7B (1)

27

11011000

Input Level 7B (2)

28

00111000

Input Level 8A (1)

29

10111000

Input Level 8A (2)

30

01111000

Input Level 8B (1)

31

11111000

Input Level 8B (2)

32

00000100

Output Level A (1)

33

10000100

Output Level A (2)

34

01000100

Output Level B (1)

35

11000100

Output Level B (2)

36

00100100

Output Level A&B (1)

37

10100100

Output Level A&B (2)

38

01100100

Group Level 1 (1)

39

11100100

Group Level 1 (2)

40

00010100

Group Level 2 (1)

41

10010100

Group Level 2 (2)

42

01010100

Group Level 3 (1)

43

11010100

Group Level 3 (2)

44

00110100

Group Level 4 (1)

45

10110100

Group Level 4 (2)

46

01110100

Group Level 5 (1)

47

11110100

Group Level 5 (2)

48

00001100

Group Level 6 (1)

49

10001100

Group Level 6 (2)

50

01001100

Group Level 7 (1)

51

11001100

Group Level 7 (2)

52

00101100

Group Level 8 (1)

53

10101100

Group Level 8 (2)

54-255

Reserved for future 
updates

       Switch Positions
ID     1 through 8        Function

Each of the predefined functions has two IDs (1) and (2) to allow two remote controls 
to perform the same function.
*Switch Positions: 1 = ON; 0 = OFF

*Switch Positions: 1 = ON; 0 = OFF

The DX-RVC is a real-time remote volume 

control for use with the DX8 and DX810 Digital 
Audio Mixer/Signal Processor. The DX-RVC can be 
programmed to operate the volume for any of the 
eight inputs, any output, or grouped outputs. The 
predefined functions are programmed via the eight 
DIP-switches on the back of the circuit board. Up 
to nine remote controls (including the DX-RVC 
and the DX-SW4) can be connected to the DX8 or 
DX810 REMOTE BUS connector.

DX-RVC

Remote Volume Control

Quick-Start Guide

SAFETY FIRST!

Before connecting and using the equipment, 

please read this Quick-Start Guide carefully 

and keep it for future reference.

WARNING!

 This equipment has been 

designed to be installed by qualified 

professionals only! There are many factors to 

be considered when installing professional 

sound reinforcement systems. Some of these 

factors include mechanical and electrical 

considerations, as well as acoustic coverage 

and performance. LOUD Technologies strongly 

recommends that this equipment be installed 

only by a professional sound installer or 

contractor.

1.  Never install, connect, or disconnect the 

remote control with the DX8 or DX810 

power supply on.

2.  Before applying power to the DX-RVC, make 

sure the wiring is correct as described in 

this Quick-Start Guide.

CAUTION:

 To avoid the risk of electric 

shock, never allow this equipment to be 

exposed to rain or dampness.

EAW Commercial  |  One Main Street  |  Whitinsville, MA 01588 USA  |   www.eawcommercial.com

TEL: toll free in US & Canada 888.337.7404  | TEL outside US 425.892.6503  |  FAX: 425.485.1152

UK  44.1268.570.808  |  FAX  44.1268.570.809

Part No. 910-298-90  Rev. B  06/04  © 2004 LOUD Technologies Inc.  All Rights Reserved.

Reviews: