background image

START-S7lT

operating guide

-2-

 

Premises

This manual provides all the specific information you 

need to familiarize yourself with and correctly ope-

rate your unit. Read it very carefully when you pur-

chase the instrument and consult it whenever you 

have doubts regarding use and before performing 

any maintenance operations.

 

Environmental protection

 measures

Information regarding the environment 

for customers within the european 

Union. european directive eC 2002/96 

requires that units bearing this symbol 

on the unit and/or on the packaging be 

disposed of separately from undifferenti-

ated urban wastes.

The symbol indicates that the product must not be 

disposed of with the ormal household wastes. The 

owner is responsible for disposing of this prod-

uct and other electrical and electronic equipment 

through specific waste collection facilities indicated 

by the government or local public agencies. Correct

disposal and recycling help prevent any potentially 

negative impact on the environment and human 

health. To receive more detailed information regard-

ing disposal of your unit, we recommend that you 

contact the competent public agencies, them waste 

collection service or the shop where you purchased

the product.

 Piccol

 

Small legend

LSO or FCA

open limit switch

LSC or FCC

Close limit switch 

START

control to drive the door 

AUTo-

choice

PARTIAL OP.

in sliding units: control partial opening

Vac

alternate current

Vdc

direct current

NC

normally closed

NO

normally open

Isolated contact

isolated from power supply

 Index

Par.

Description

Page

1

Introduction

3

1.1

Safety precautions

1.2

Symbols and warning

1.3

Type of installation

2

Description of the connections

4

2.1

Product description

2.2

Field of application

2.3

Technical description

3

Premises

5

3.1

Preliminary checks

3.2

Type of electrical wires

3.3

notes on connections

4

Installation

6

4.1

Scheme of the control unit and electrical connections

4.2

Adjustment of the FoRCe, SPeed and SlowInG down

4.3

description of the electrical connections

4.4

Checking connections

4.5

Connection of the PoweR SUPPlY and BATTeRY

8

4.6

Connection of the MoToR

4.7

Connection of the encoder

4.8

ConneCTIon oF THe lAMPS

4.9

Connection of the lIGHT

9

4.10

Connection of the electrical lock

4.11

Connection of the SToP

4.12

Connection of the open and Close limt switches

10

4.13

Connection of the PHoTo A (only closing)

4.14

Connection of the START commands

11

4.15

Connection of the CloSInG / PedeSTRIAn

4.16

Power supply of the accessories

4.17

Connection of the AnTennA

5

Function

13

5.1

logic of function dIPA

14

5.2

exclusion of the inputs SToP-FoTo-FCA-FCC dIPB

15

6

Managing of the REMOTE CONTROL DIP9 OFF

16

6.1

Cancellation of the memory

6.2

Activation of the codes

6.3

Memorization of the codes

17

7

Turn on and programm

18

7.1

Memorization of the working time

7.2

Memorization of the working time with a command START

19

7.3

Use the input CloSe for PARTIAl oPenInG

20

7.4

Go back to the InPUT CloSe for CloSe FUnCTIon

7.5

Increase the PAUSe TIMe

21

7.6

Fixed light or flashing

8

Note

9

Dichiarazione CE di conformità

22

Summary of Contents for Nologo START-S7LT

Page 1: ...for low tension Motor Input for low tension Motor Power supply of the accessories max 1 6 A Isolated contact for lamps Power supply of the accessories max 1 6 A Isolated contact for lamps Isolated con...

Page 2: ...normally closed NO normally open Isolated contact isolated from power supply Index Par Description Page 1 Introduction 3 1 1 Safety precautions 1 2 Symbols and warning 1 3 Type of installation 2 Descr...

Page 3: ...te or door even if the electrical limit switches should fail or during manual operations 1 1 Safety precautions READ CAREFULLY THE OPERATING MANUAL Read carefully this manul before installation and ke...

Page 4: ...l motors that are designed for internal electronics The design has adapted the most advanced techniques to guarantee utmost immunity vs noise maximum operating fl exibility and to make a wide choice o...

Page 5: ...r tight If they are not used the inputs to the Normally Closed NC contacts must be jumpered to the common If the same input has more than one contact NC they are placed in series If they are not used...

Page 6: ...x FORCE Min SPEED Min OFF slowing MAX slowing SPEED Max 4 2 Adjustment of the FORCE SPEED and SLOWING DOWN 1 2 3 4 J12V BAT BAT Use the correct cable to connect the battery and re spect the polarity D...

Page 7: ...n services and securities Antena 18 Positive pole antena 5 Vdc 19 Power supply of the encoder Sgn encoder 20 encoder signal 5 Vdc 21 Power supply of the encoder START S7lT operating guide 7 4 3 Descri...

Page 8: ...21 20 Signal for encoder power supply of the encoder 5V power supply of the encoder For a correct use of the encoder we recommend to ready the man ual The following control board can be powered 12 24...

Page 9: ...d in series If the input STOP is not used bring DIP 1B in ON If you bring DIP8 in ON you can connect a signa light which will be lit on before opening and two minutes after closing Signal light activa...

Page 10: ...switch and DIP 4B in ON for close limit switch 6 7 8 5 10 11 12 9 14 15 16 13 18 17 CLOSE OPEN power supply of the photo beam TX 4 13 Connection of the PHOTO A only closing Photo beam receivers N C te...

Page 11: ...to the terminal board 15 connect it in parallel 10 11 12 14 15 16 13 18 17 4 15 Connection of the CLOSING PEDESTRIAN The CloSe input can be used as PedeSTRIAn com mand a command to switch to CloSe Pe...

Page 12: ......

Page 13: ...ral reverses the motor direction and executes a closure at low speed during the closing phase of the central reverses the motor direction whether oPenS CloSeS during the slowdown that the intervention...

Page 14: ...is open stop close stop open It recloses automatically at the end of the pause time 3 ON reversing and closing stroke DIP 8 With DIP 8 in ON It activate the reversing stroke when it reaches the close...

Page 15: ...or deactivate the courtesy light ON 2 1 4 3 6 5 8 7 10 9 ON 2 1 4 3 6 5 8 7 10 9 8 OFF electrical lock It permet the electrical lock 9 ON memorization of the time and position Memorization of the work...

Page 16: ...egularly and it is ready to manage the fixed code 1 regular flash see next chapter The memory is cancelled 1 Press and keep presse the button P on the control board LED L1 will lit on 2 In these 6 sec...

Page 17: ...t means that the memory code is full and it doesn t accept any remote controls For 20 bits the capacity of the code is 22 codes If you need to memorize more codes you need to install a supplementary r...

Page 18: ...r supply to the control card Put in ON the DIP9 and you can set up working time and pause time position of the slow down activation or deactivation of the lamp in pause time 7 1 Memorization of the wo...

Page 19: ...e stroke press the START comand The gate stops 5B If the open limit switch is connected you don t need to do nothing as the limit switch boost the programm 6 Let the time goes until the gate is openin...

Page 20: ...for the automation to stop automatically The gate is closed 8 Put in OFF the DIP9 to return in the standard function The signal light turned off and LED L1 will starts again End of the memorization o...

Page 21: ...ll lit on longer It is possible to increase the pause time up to 20 seconds 4 pressions x 5 sec If 20 seconds are not sufficient you can increase the pause time making a new cycle The pause time chang...

Page 22: ...r THE PRODUCT COMPLIES with what is outlined in the European Community directives 2006 95 CE EEC DIRECTIVE 2006 95 ISSUED BY THE EUROPEAN COUNCIL on December 12 2006 harmonizing the legislation of the...

Page 23: ...sous la seule responsabili du constructeur et si applica ble de son repr sentant autoris Busto Arsizio Va Italia 01 04 2013 ERNESTINO BANDERA Administrateur KONFORMIT TSZERTIFIKAT Der Unterzeichner b...

Page 24: ...1052 Busto Arsizio VA Italia tel 39 0331 683310 fax 39 0331 684423 posta ebtechnology it www ebtechnology it NOLOGO S r l via Cesare Cant 26 20020 Villa Cortese MI Italia tel 39 0331 430457 fax 39 033...

Reviews: