Installation of the control unit
25
23
26
3.1 Connection of the TENSION
The control unit can be powered
12 Vac/24 Vac
12 Vac:
Put the
J12/24
as in the picture
Set to
“0”
the set up
S 21
.
24 Vac:
Put the in
J12/24
as shown
Set
“1”
the set up
S 21.
24
3.2 Connections of the MOTORS
21
20
22
19
MOT 1
mOT 2
Pay attention not invert the poles OPEN and CLOSE.
When the connection is finished, in case of doubts put manually the
gate in the middle and read
Paragraph 4.2
to check the right direction
of the motors.
3.5 Connection of the STOP device
Connection of the
STOP
control
Button:
stop the control unit until a new contro.
Switch:
it stops the automation until a new control.
If the input STOP
is not used,
put “0” in the set up S15
29
27
30
28
230V input Primary
Transformer
Low Tension
input for transformer
BATTERY
+
-
Connection of the safety devices requires the use of any
push-button or N.C. (normally closed) contact.
When there are several safety devices, they are connected
in series.
3 4 5 6 7 8 9 10
The power supply line has to be protected from a magneto-termic switch or from a couple of 5A fuses.
A differential switch is useful if it is already available in the installation.
230Vac
3.3 ANTENNA connections
In case of using a cable (as antenna) for the frequency
433.92mhz, you can cut at 17cm and connect it to the ter
-
minal board 1.
1 2 3
3.4 Power supply of the accessories
13 14 15 16
+
-
Connect the terminal board
13
and
14
to power the accessories.
The tension on top of the terminal
boards is up of the transformer.