7
3.6 Connection of the COURTESY LIGHT
Set up
Val
Description
S 03 1
Courtesy light in the
LAmP output
In the terminal board
17
and
14
tension is available up to
255s
after.
Standard value
0s
T 18
Working time
Courtesy light
Can be set up from
0 to 255 s
Standard value
120s
13 14 15 16 17 18
To activate the courtesy light function, as shown in the picture
S03
3.7 Connection of the LAMP
13 14 15 16 17 18
+
-
+
-
Set up
Value
Description
S 25
1
Activate the Lighting
0
Deactivate the lighting
Standard
Set up
Val
Description
S 05 1
Lamp
in pause time
The light is working in the
pause time, too.
(Standard value 0)
To activate the function
“lamp during pause time”
put
S 05
at
1
, to deactivate the function put
S05
at
0
.
Put the set up
S25
at
1
, if you use a lamp without flashing light, otherwi
-
se put the
S25
at
0
.
3.8 PRE-LIGHTING
To increase or reduce pre-lighting time, put
T 15
and
T 16
as follow:
Set up
Description
T 15
Pre-lighting time
when CLOSED
Set up from
0 a 10 s
Standard Value
2 s
T 16
Pre-lighting time
when the gate is OPEN
Set up from
0 a 10 s
Standard value
2 s
3.9 Connection of a 24 light when the gate is open and when it is moving
13 14 15 16 17 18
+
-
Set up
Value
Description
S 07 1
Fix light
The Fix light indicates the gate
opens.
0
Flashing
light
The output light is flashing
(standard version)